OM-231185 Page 42
AB. Network Wait
NET
WAIT
Indicates that the UIM board PC7 is no longer communicating with the PCM board PC4 by DeviceNet.
AC. Cycle Power
CYCL
PWR
Request to cycle power from the welding power source. Turn unit power off and back on again.
AD. PCM Bus Communication
— —
— —
— — Indicates no error message on the displays. PCM board PC4 DeviceNet has gone offline. Turn welding power
source off and back on again to clear the communication error.
AE. RIO Bus Communication
— —
— —
— — Indicates no error message on the displays. RIO DeviceNet is losing packets of data. Turn welding power source off
and back on again to clear the communication error.
AF. Wire Feed Bus Communication
— —
— —
— — Indicates no error message on the displays. WFM board PC6 DeviceNet is losing packets of data. Turn welding
power source off and back on again to clear the communication error.
AG. UIM Bus Communication
— —
— —
— — Indicates no error message on the displays. UIM board PC7 DeviceNet is losing packets of data. Turn welding pow-
er source off and back on again to clear the communication error.