![Miller Electric MOG-200C Owner'S Manual Download Page 9](http://html1.mh-extra.com/html/miller-electric/mog-200c/mog-200c_owners-manual_1796671009.webp)
OM-805 Page 3
3-3.
Preparing And Connecting Weld Input/Output Cables
WARNING
ELECTRIC SHOCK can kill.
•
Do not touch live electrical parts.
•
Turn Off welding power source, and disconnect input power before making any weld output connections.
swarn12.1 2/93
A. Weld Input/Output Cables
1
Weld Input Cable
2
Work Cable
3
Weld Output Cable
If necessary, use Table 3-1 to se-
lect proper cable size.
Use shortest cables possible.
Do not use damaged cables.
4
Terminal Lug
Use lugs of proper amperage ca-
pacity and hole size for connecting
to common work, electrode hold-
er(s), and weld output terminals (if
applicable).
5
Common Work Connection
Connect work cable to common
work according to codes.
6
Insulated Electrode Holder
7
GTAW Torch
Install according to manufacturer’s
instructions.
8
Female Camlok Connector
Install onto weld input cable as
shown in Figure 3-4.
9
Weld Input Receptacle
Connect cable to weld input recep-
tacle on rear panel of grid.
10 Male Camlok Connector
Install onto weld output cable as
shown in Figure 3-5.
11 Electrode Receptacle
Connect weld output cable to Elec-
trode receptacle.
S-0836-A
Tools Needed:
Or
3
4
6
7
8
10
4
1
5
2
8
9
11
Figure 3-3. Weld Input/Output Cables For Resistance Grid