Ælogic Operation 

 

Millennia’s 

Ælogic remote control software is 

intuitive. What follows is an in-depth description of 

its available functions. 

Refer to Appendix for a list of 

keyboard shortcuts.

 

 

Unit Status Window 

 

The example screen above 

shows a Unit Status window in which seven HV-316 

units (112 channels) are connected to the remote 

network. The Unit Status window displays an icon of 

each HV-316 unit on the network. The status of each 

HV-316 

is represented by its icon’s color code, as 

follows: 

 

Red Icon 

 

“Unit 

ID Has a Conflict with Another 

Unit

.  If two or more HV-316s share the same Unit 

ID number or IP address, their icons will turn red 
and will show identical IDs or IP addresses until the 

conflict is resolved.   

 

Setting a Unit ID or IP address must be done locally 

on each HV-316. Other errors could also cause a red 

icon, such as over-temperature, power supply out of 

range, other networking errors, etc.  

 

Green Icon 

 

Functioning Normally

. Remote unit 

functioning normally. 

 

Flashing Green Icon

 

 HV-3R only. 

Functioning 

Normally, Local 

Mode”

. Remote unit is functioning 

normally but is in the local mode. 

 

HV-3R only: if the unit is in Local mode when Ælogic 

is started, it won’t appear.  Be sure to change the 

unit to Remote mode so the software can recognize 

the HV-3R. 

 

Purple Icon 

 

Unit ID Is 

Offline”

. A unit was 

previously connected to the network and set to this 

Unit ID but is missing from the network. It was 

either turned off or the Ethernet was disconnected or 

both. 

 

Blue Icon

 

 The Redundant Power Supply is 

powering the unit and the internal power supply is 

offline due to either failing or losing AC mains power. 

 

Gray Icon 

 

“Unit 

ID Is 

Inactive”

.  No unit is 

connected to the network and set to this Unit ID. 

 

Unit ID Conflict

 

 

If more than one unit has the 

same ID number this warning will 
appear.  You must correct the 

problem before you can continue. 

 

 

Unit Status Dialog 

 

Double left mouse click on 

any icon brings up that unit’s 

Unit Status dialog box 

displaying the following information: 

 

1.

 

Unit Functionality 

2.

 

48v Monitor (HV-3R) 

3.

 

24v Monitor (HV-3R) 

4.

 

5v Monitor (HV-3R) 

5.

 

3.3v Monitor (HV-3R) 

6.

 

Temperature 

7.

 

MAC Address 

8.

 

Firmware Version 

9.

 

Output Format 

10.

 

IP Address 

11.

 

Split Gain Offset

    

Scene Window 

Unit Status Window 

Control Section 

Summary of Contents for HV-316

Page 1: ...HV 316 Remote Control Microphone Preamplifier Owner s Manual...

Page 2: ...Green Icon 9 Purple Icon 9 Blue Icon 9 Gray Icon 9 Unit ID Conflict 9 Unit Status Dialog 9 Overview 10 Control Section 10 Control Layout 10 Unit Naming and Unit Name Dialog Box 11 POLarity Flip 11 PAD...

Page 3: ...ge Do not attempt to use the HV 316 in near or around water or in unusually moist environments such as near a sink or swimming pool Prevent liquids or any other materials or objects from spilling or f...

Page 4: ...s shipments be honored more than 10 days after ship date Read this manual carefully and completely before attempting to use the HV 316 Improper operation could result in damage to product It is the us...

Page 5: ...ngs Static IP address 192 168 1 221 Netmask 255 255 255 0 HV316 must be powered off Insert a small non metallic object into the reset opening on the read of the unit You should feel a slight click whe...

Page 6: ...n the protection software on when finished You need to allow logic all permissions to access your network Failing to do so will prevent the software from seeing the Millennia Preamps connected If you...

Page 7: ...68 1 2nn HV 316 ID nn Be sure the computer s wired Ethernet connection is set to IP address 192 168 1 200 There are many ways to do this and Microsoft occasionally changes the setup menus As of this w...

Page 8: ...o access the network that you have chosen to use your HV 316s Dynamic Host Configuration Protocol DHCP is also an option for IP Address but we don t recommend using it unless you are familiar with net...

Page 9: ...n HV 3R only Functioning Normally Local Mode Remote unit is functioning normally but is in the local mode HV 3R only if the unit is in Local mode when logic is started it won t appear Be sure to chang...

Page 10: ...e the scroll bar at the bottom of the screen It allows the user to quickly scroll to any unit in the network You can also move the Control Section by using the Left and Right arrow keys on the keyboar...

Page 11: ...3 of that channel s mic input Button illuminates yellow You must disable RBN before 48V can be enabled Caution do not insert or extract a mic with the phantom power on It can damage the microphone an...

Page 12: ...d the channel reverts to linked mode Linked Mute Linked Mute parameters will turn on and off together unless Mute linked channels is unchecked in the Preferences dialog box Setup Preferences Mute link...

Page 13: ...ile Save ctrl S will save any updates or changes to the project unless a new name is desired use File Save As shift ctrl S Scene Window Underneath the Scene Window there are four buttons Recall New De...

Page 14: ...onal Appending and Saving Scenes Whenever a change is made to any parameter or function an asterisk will appear next to the active scene in the Scene Window with the exception of the Blank Scene The a...

Page 15: ...Z Undo 10 levels Double Click Group Title in Link Matrix Lists channels that are members of the group Double Click on unit icon in Unit Status box Gives voltage temperature and network data of unit Do...

Page 16: ...og output option 22 dBu analog option Phantom Input Impedance 1 kHz 6 750 ohms Output Impedance 24 3 Ohms analog option Phantom Powering 48 V dc 2 V dc 15 ma per channel Power Consumption 100 watts ma...

Page 17: ...ll be accompanied by Windows based control software called Logic offering visual access to hardware control functionality and scene management The device shall be the Millennia HV 316 Warranty US and...

Reviews: