Milennia HV-316 Owner'S Manual Download Page 8

Millennia Media HV-316                                                                                                          page 8 of 17 

If you have everything set correctly when Ælogic 

opens, the icon of the HV-

316’s Unit ID 

in the Unit 

Status window will turn green. Double click on it to 

open the Unit Status dialog box. 

 

 

 

 

Set the HV-316 IP address and click OK 

  

 

You will lose connection if you select an IP 

Address other than 192.168.1.xxx

 and will need 

to change your computer

’s IP Address

 to access the 

network that you have chosen to use your HV-316s. 

 

Dynamic Host Configuration Protocol (DHCP)

 is 

also an option for “IP Address”, but we don’t 

recommend using it unless you are familiar with 

networking and have the proper network hardware 

that supports it. 

 

Ethernet and MIDI control cannot be used 

simultaneously

 

 only one remote control protocol 

can be used in an HV-316 network. 

 

 

Default Settings 

 

The HV-316 is shipped to 

startup with the default settings: 

 

 

All functions turned off (POL, PAD, 48V, 

MUTE, SPLIT, SAFE, RBN and HPF). 

 

IP Address set to 192.168.1.221 

 

Netmask 255.255.255.0 

 

Unit ID 1 

 

 

Summary of Contents for HV-316

Page 1: ...HV 316 Remote Control Microphone Preamplifier Owner s Manual...

Page 2: ...Green Icon 9 Purple Icon 9 Blue Icon 9 Gray Icon 9 Unit ID Conflict 9 Unit Status Dialog 9 Overview 10 Control Section 10 Control Layout 10 Unit Naming and Unit Name Dialog Box 11 POLarity Flip 11 PAD...

Page 3: ...ge Do not attempt to use the HV 316 in near or around water or in unusually moist environments such as near a sink or swimming pool Prevent liquids or any other materials or objects from spilling or f...

Page 4: ...s shipments be honored more than 10 days after ship date Read this manual carefully and completely before attempting to use the HV 316 Improper operation could result in damage to product It is the us...

Page 5: ...ngs Static IP address 192 168 1 221 Netmask 255 255 255 0 HV316 must be powered off Insert a small non metallic object into the reset opening on the read of the unit You should feel a slight click whe...

Page 6: ...n the protection software on when finished You need to allow logic all permissions to access your network Failing to do so will prevent the software from seeing the Millennia Preamps connected If you...

Page 7: ...68 1 2nn HV 316 ID nn Be sure the computer s wired Ethernet connection is set to IP address 192 168 1 200 There are many ways to do this and Microsoft occasionally changes the setup menus As of this w...

Page 8: ...o access the network that you have chosen to use your HV 316s Dynamic Host Configuration Protocol DHCP is also an option for IP Address but we don t recommend using it unless you are familiar with net...

Page 9: ...n HV 3R only Functioning Normally Local Mode Remote unit is functioning normally but is in the local mode HV 3R only if the unit is in Local mode when logic is started it won t appear Be sure to chang...

Page 10: ...e the scroll bar at the bottom of the screen It allows the user to quickly scroll to any unit in the network You can also move the Control Section by using the Left and Right arrow keys on the keyboar...

Page 11: ...3 of that channel s mic input Button illuminates yellow You must disable RBN before 48V can be enabled Caution do not insert or extract a mic with the phantom power on It can damage the microphone an...

Page 12: ...d the channel reverts to linked mode Linked Mute Linked Mute parameters will turn on and off together unless Mute linked channels is unchecked in the Preferences dialog box Setup Preferences Mute link...

Page 13: ...ile Save ctrl S will save any updates or changes to the project unless a new name is desired use File Save As shift ctrl S Scene Window Underneath the Scene Window there are four buttons Recall New De...

Page 14: ...onal Appending and Saving Scenes Whenever a change is made to any parameter or function an asterisk will appear next to the active scene in the Scene Window with the exception of the Blank Scene The a...

Page 15: ...Z Undo 10 levels Double Click Group Title in Link Matrix Lists channels that are members of the group Double Click on unit icon in Unit Status box Gives voltage temperature and network data of unit Do...

Page 16: ...og output option 22 dBu analog option Phantom Input Impedance 1 kHz 6 750 ohms Output Impedance 24 3 Ohms analog option Phantom Powering 48 V dc 2 V dc 15 ma per channel Power Consumption 100 watts ma...

Page 17: ...ll be accompanied by Windows based control software called Logic offering visual access to hardware control functionality and scene management The device shall be the Millennia HV 316 Warranty US and...

Reviews: