Link Assignment 

 

The Link parameter provides a 

Gain and Mute linking utility. Linking applies to Gain 

and Mute parameters only; no other parameters are 

linkable. 

 

The LINK button links and unlinks a channel from a 

selected 

link group

.  There are ten selectable link 

groups that can be chosen from the drop-down box 

next to the LINK button or the 

Link Matrix

.  When a 

link group is chosen, the LINK button is 

automatically selected and illuminates red. One link 

group can be assigned per channel. If no link group 

is selected, a depressed LINK switch will effectively 

do nothing.   

 

Linked Gain

 

 Linked Gain faders move together 

maintaining the same distance they had when first 

linked together. Once one fader reaches the upper or 
lower extreme, the other faders in the same link 

group stop moving in that direction. 

 

Linked Gains can be trimmed by holding down the 

Alt key while using the left mouse button. When the 

Alt key is released, the channel reverts to linked 

mode. 

 

Linked Mute

 

 Linked Mute parameters will turn on 

and off together unless “Mute linked channels” is 

unchecked in the Preferences dialog box (Setup> 

Preferences>

“Mute linked channels”).  If this box is 

unchecked, the mute parameters will act 

independently just like the other parameters. 

  

Scribble Strip

 

 (right-click on scribble strip) 

A text box in which channels can be named and 

notes can be written and stored. See th

screenshot 

on the previous page. 

 

T

o name multiple channels quickly, “Prev” and 

“Next” buttons allow the user t

o scroll through 

channels without closing the dialog box. If a channel 
has been re-named from the default, the new 

Channel Name will now be displayed in the Unit 

Name box. The Naming Window can also be 

accessed from the pull-down menus (Edit>Channel 

Naming). 

 

 

 

 

 

 

 

 

 

Link Matrix

  

 

The Link Matrix dialog box provides for easier linking 

and unlinking of channels and can be accessed via 

shortcut ctrl-L or from the pull-down menus 

(Edit>Link).   

 

 

Name a Link Group by right clicking a Link 

Group number.  

 

See the members of a group by double clicking 

the group’s name.  

 

 

Right click a link to bring up the channel naming 

dialog box. 

 

 

Summary of Contents for HV-316

Page 1: ...HV 316 Remote Control Microphone Preamplifier Owner s Manual...

Page 2: ...Green Icon 9 Purple Icon 9 Blue Icon 9 Gray Icon 9 Unit ID Conflict 9 Unit Status Dialog 9 Overview 10 Control Section 10 Control Layout 10 Unit Naming and Unit Name Dialog Box 11 POLarity Flip 11 PAD...

Page 3: ...ge Do not attempt to use the HV 316 in near or around water or in unusually moist environments such as near a sink or swimming pool Prevent liquids or any other materials or objects from spilling or f...

Page 4: ...s shipments be honored more than 10 days after ship date Read this manual carefully and completely before attempting to use the HV 316 Improper operation could result in damage to product It is the us...

Page 5: ...ngs Static IP address 192 168 1 221 Netmask 255 255 255 0 HV316 must be powered off Insert a small non metallic object into the reset opening on the read of the unit You should feel a slight click whe...

Page 6: ...n the protection software on when finished You need to allow logic all permissions to access your network Failing to do so will prevent the software from seeing the Millennia Preamps connected If you...

Page 7: ...68 1 2nn HV 316 ID nn Be sure the computer s wired Ethernet connection is set to IP address 192 168 1 200 There are many ways to do this and Microsoft occasionally changes the setup menus As of this w...

Page 8: ...o access the network that you have chosen to use your HV 316s Dynamic Host Configuration Protocol DHCP is also an option for IP Address but we don t recommend using it unless you are familiar with net...

Page 9: ...n HV 3R only Functioning Normally Local Mode Remote unit is functioning normally but is in the local mode HV 3R only if the unit is in Local mode when logic is started it won t appear Be sure to chang...

Page 10: ...e the scroll bar at the bottom of the screen It allows the user to quickly scroll to any unit in the network You can also move the Control Section by using the Left and Right arrow keys on the keyboar...

Page 11: ...3 of that channel s mic input Button illuminates yellow You must disable RBN before 48V can be enabled Caution do not insert or extract a mic with the phantom power on It can damage the microphone an...

Page 12: ...d the channel reverts to linked mode Linked Mute Linked Mute parameters will turn on and off together unless Mute linked channels is unchecked in the Preferences dialog box Setup Preferences Mute link...

Page 13: ...ile Save ctrl S will save any updates or changes to the project unless a new name is desired use File Save As shift ctrl S Scene Window Underneath the Scene Window there are four buttons Recall New De...

Page 14: ...onal Appending and Saving Scenes Whenever a change is made to any parameter or function an asterisk will appear next to the active scene in the Scene Window with the exception of the Blank Scene The a...

Page 15: ...Z Undo 10 levels Double Click Group Title in Link Matrix Lists channels that are members of the group Double Click on unit icon in Unit Status box Gives voltage temperature and network data of unit Do...

Page 16: ...og output option 22 dBu analog option Phantom Input Impedance 1 kHz 6 750 ohms Output Impedance 24 3 Ohms analog option Phantom Powering 48 V dc 2 V dc 15 ma per channel Power Consumption 100 watts ma...

Page 17: ...ll be accompanied by Windows based control software called Logic offering visual access to hardware control functionality and scene management The device shall be the Millennia HV 316 Warranty US and...