page 26
4-5 Configuring the Trigger
To Set the
Trigger Position
in the TS3:
1. Navigate to the Control Menu.
2. Select
Trigger Position
.
3. Select Start, 10%, 50%, 90% or End.
Note: When controlling the camera via Web-
Application or
F
as
M
otion so
are, it is possible
to position the tri
g
ger in 1% or even 1-frame
increments.
Enabling the External Trigger
There are times when manually p
r
essing the
trigger bu
tt
on is not practi
c
al. The camera may be
mounted in a location th
a
t is difficult or da
ng
erous to reach, or it may be that the precision
required to acti
v
ate the trigger is much easier to maintain through electrical means.
1. Navigate to the Control Menu.
2. Select Ext. Trigger.
3. If Disabled, click on the “Disabled” bu
tt
on.
It will turn green and the text will change to
“Enabled.”
4. The next bu
tt
on to the right will either say
Rising or Falling Edge. If you need to change
the setti
ng
, click on this bu
tt
on to open the
dialog box pictured in “Figure 4-6: External
Trigger”.
Please refer to
“Appendix D: Power and I/O Connections” on page 82 for connection information
and warnings.
Figure 4-5:
Trigger Position
Figure 4-6:
External Trigger
T3 User Manual
11S-3000M
Summary of Contents for eosens TS3
Page 1: ...User Manual 2013 3 110S 3000M eosens TS3 High Speed Handheld Camera...
Page 15: ...11S 3000M page 5 Figure 1 4 TS3 Side View Door open Figure 1 5 TS3 Bottom View T3 User Manual...
Page 105: ...TS3 User Manual Figure 10 4 High Mid and Low 8 Bits of the same Image...
Page 120: ...TS3 User Manual 11S 3000M page 111...