![MIKOM MR301B Power User Manual Download Page 59](http://html1.mh-extra.com/html/mikom/mr301b-power/mr301b-power_user-manual_1793935059.webp)
User’s manual for Repeater MRx01B Power
M0079A1A.doc
Id.-No. 151775
Page 59
10-March-00
ELECTRICAL SPECIFICATIONS
MR401B Power
Frequency range Id-No:150043
150044
150045
150046
UL:1710-1740 MHz; DL:1805-1835 MHz
UL:1721,7-1751,7MHz; DL:1816,7-1846,7 MHz
UL:1730-1760 MHz; DL:1825-1855 MHz
UL:1751,5-1784,9 MHz; DL:1846,5-1879,9 MHz
Bandwith
Up to 35 MHz
Frequency selectivity;
Gain outside operating band
±
400 kHz: 50 dB max.;
±
600 kHz: 40 dB max.
±
1000 kHz: 35 dB max.;
±
5000 kHz: 25 dB max.
Gain (nominal)
85 dB
Gain adjust
0 to 30 dB in steps of 2 dB
Gain variation over frequ. and temp.
± 2.5 dB (± 3.5 dB at extreme temperature range)*
Tolerance per step
±
0.5 dB from 0 to 6 dB attenuation
±
2.0 dB from 8 to 30 dB attenuation
Delay
6
µ
sec.max.
Delayripple
150 ns
30 dBm (@ 25° C)
Output power ALC limit (test case)
at 2 equal carriers
+27,5 dBm / +27,5 dBm*
ICP3
57 dBm @ max. gain
ALC limit tolerance of frequency
and temperature
±
3 dB
ALC overload reaction time delay
3 msec. (others available on request)
Noise figure
6 dB @ max. gain;
8 dB @ 75 dB gain;
Test coupler
30 dB
Return loss (@ 25° C amb. temp.)
15 dB
Power Supply
230 Vac
±
15% / 40.-.65 Hz;
Option:
24 Vdc or 42 - 60 Vdc or 80 – 130 Vdc,
115 Vac
±
15% / 40.-.65 Hz or 185 – 320 Vac /
40 - 65 Hz
Power consumption (1 module)
160 Watts
Remote control interface
SM 2009
Connectors
7/16 female; N as an option
Environmental and Safety
see Environmental and Safety leaflet for MIKOM
outdoor cell enhancers
Built in test equipment
Current monitor
•
synthesizer lock monitor
•
temperature
•
ALC active
Alarm forwarding
Potential free relay contact and automatic alarm
call via RS232 or PCMCIA interface
Control functions
Gain
•
Center frequency
•
ALC threshold
* Normal temp.range
+ 5° C to + 40°C
Extreme temp.range- 33° C to + 50° C