![MIKOM MR301B Power User Manual Download Page 37](http://html1.mh-extra.com/html/mikom/mr301b-power/mr301b-power_user-manual_1793935037.webp)
User’s manual for Repeater MRx01B Power
M0079A1A.doc
Id.-No. 151775
Page 37
10-March-00
5.2.2
Power connection
A firmly installed mains cable 3 x 1.5 mm² is used, which is fed into the housing through a
watertight cable gland. Due to safety reasons the power supply lead has to be protected by two
8 A fuses. Inside the Repeater, mains are connected to a screw terminal.
See figure 5-5 Screw terminal for the position of the two 8 A fuses.
Before connecting electrical power to the Repeater grounding has to be performed. The
Repeater is equipped with a firmly connected power cord 3 x 1.5 mm². Due to safety reasons
the power supply lead of the Repeater has to be protected with two 8 A fuses, type MT. In the
event the length of the power cord should not be sufficient it can be replaced by a longer
cable.
figure 5-5 Screw terminal
F
Note:
If the power supply lead has to be replaced use a cable of the same quality.
5.2.3
Connection of the antenna cables
The Repeater has two female antenna connectors 7/16 (optionally N). For mounting the
corresponding cable connectors we recommend to refer to the applicable documentation of
the respective connector manufacturer. The bending radius of the antenna cables must remain
within its specification. This will warrant proper operation of the system; otherwise changes
in the electrical behaviour of the cable might occur which could cause malfunction of the
Repeater system.
Fuses F1 and F2