![MIKOM MR301B Power User Manual Download Page 54](http://html1.mh-extra.com/html/mikom/mr301b-power/mr301b-power_user-manual_1793935054.webp)
User’s manual for Repeater MRx01B Power
M0079A1A.doc
Id.-No. 151775
Page 54
10-March-00
8.9 Replacement of power supplies
F
Note:
Ensure that mains are disconnected.
Open the Repeater to get access to the devices.
Remove all connected cables from the clamps of the power supply. Try to loose the plug by
means of a small screwdriver placed between the plug and socket.
ON
Fuse 10A / 35V
figure 8-9 Power supply
The power supply is fixed to the Repeater housing by means of two special nuts M4. After
loosen the screws the power supply can be removed. To open these screws a special key with
a spherical head is required. Place a small screwdriver between the Repeater housing and the
power supply to loose the device.
figure 8-10 Position of special-nut M4
F
Note:
Don’t forget to put heat conducting paste on the mounting side for
installation of a new power supply. Use the conducting paste, which is
included in the spare parts kit.