background image

                 

Programming manual V1.1

 

 

 

www.parapulser.com 

2

 

8.  Programming-mode 

 

To be able to perform at the 

Parapulser

 a programming, adjustment or readout, 

the 

Programming-mode 

has to be activated previously: 

8

 

a)

 

Programming-mode

 activate  

Æ

 

PROG

-key press at switch on of the 

Parpulser

  

 

3

 seconds, until 

3

 Piep-tones are audible and all 

3

 

 

LEDs (

=

=

=

) light up permanently. 

8

 

b)

 

Programming-mode

 terminate 

Æ

  Parapulser 

switch off with

 on/OFF

-key, or... 

 

Æ

 

PROG

-key 

3 x 

quick press if all 

3

 LEDs  

 

 

(

=

=

=

) are on permanently: 

Parapulser 

switches 

 

 

to normal operating mode. 

 

Programming-keys: 

Brief description: 

PROG

  - 

Programming-modus

 activate/ terminate 

 

- Input-mode abort 

 

- One digit back 

 

Parapulser

 switch off 

 

sel

 

- Number (0

 

-

 

9) / memory (1-12) select 

HZ

 

- Frequency-input activate/ complete 

 

rest

 

- Pulse reservoir / Frequency value readout  

set

 

- selected number (0-9) confirm 

CODE

  - Input-mode (e.g. for Code-number) 

 

  

 

activate

 

 
 

8.1   

Overview programming-options 

 

Chapter

 

Programming-Option 

Number input / -readout 

8.2 

Puls frequency program 

Z

 

1

 

Z

 

2

  Z

 

3

  Z

 

4

  Z

 

5

 

 

 

 

 

 

8.2 

Puls frequency readout 

A

 

1

 

A

 

2

  A

 

3

  A

 

4

  A

 

5

 

 

 

 

 

 

8.4 

Acoustic Puls counter program 

Z

 

1

 

Z

 

2

  Z

 

3

  Z

 

4

 

 

 

 

 

8.4

 

Acoustic Puls counter readout 

A

 

1

 

A

 

2

 

A

 

3

 

A

 

4

 

 

 

 

 

8.5

 

Loudness operating-signals 

 

 

 

 

 

 

 

 

8.5

 

Loudness acoustic pulse counter 

 

 

 

 

 

 

 

 

8.6

 

Yellow LED “

ON

” at pulse consuming 

 

 

 

 

 

 

 

 

8.7

 

Upgrade-frequency readout 

A

 

1

 

A

 

2

 

A

 

3

 

A

 

4

 

 

 

 

 

8.8

 

Software version readout 

A

 

1

 

A

 

2

 

 

 

 

 

 

 

8.8

 

Serial number readout  

A

 

1

 

A

 

2

 

A

 

3

 

A

 

4

 

A

 

5

 

A

 

6

 

 

 

 

Checksum readout

 

1)

 

A

 

1

 

A

 

2

 

A

 

3

 

A

 

4

 

A

 

5

 

A

 

6

 

A

 

7

 

A

 

8

 

i

 

PROG

 

-key 

sel

 

-key 

HZ 

-key 

rest

  -key 

se

t

 

-key 

CODE 

-key 

Summary of Contents for Parapulser

Page 1: ...M a g n e t i c P u l s e r Based on the researches of Dr R C Beck P r o g r a m m i n g V 1 1 04 2018 TAKE BACK YOUR POWER...

Page 2: ...adout 12 5 8 5 Volume adjustment of operating signals 13 and of the pulse counter 14 6 8 6 Yellow LED ON when consuming pulses 15 6 8 7 Upgrade Frequenz increase readout 16 7 8 8 Software version 17 o...

Page 3: ...arapulser switch off sel Number 0 9 memory 1 12 select HZ Frequency input activate complete rest Pulse reservoir Frequency value readout set selected number 0 9 confirm CODE Input mode e g for Code nu...

Page 4: ...into a free memory location 1 Write down the frequency value in the form of a 5 digit number e g 07843 2 Activate Programming mode see 8a on page 2 3 Select free memory location sel key press so ofte...

Page 5: ...put mode is aborted when the PROG key is shortly pressed after a jump back to a previous digit has taken place see c All so far made inputs will be rejected and the number of the selected memory locat...

Page 6: ...re audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 4 6 digit number sequence input Jump to chapter 8 13 on page 11 and follow the instr...

Page 7: ...2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 3 2 digit number 13...

Page 8: ...rade frequency increase 1 Order 6 digit upgrade CODE number at your Parapulser salesman 2 Enter the CODE number as described at 8 13 page 11 After successful CODE input the increased upgrade frequency...

Page 9: ...long Beeep tone signalizes that all digits have been readout The input mode is automatically terminated and all three LEDs light up again If the 2 digit software version has been readout the version...

Page 10: ...t of magnetic pulses Needed pulse amount number of application days x number of daily applications x pulse frequency in Hz x amount of minutes per application x 60 Example How many magnetic pulses are...

Page 11: ...8 Input of a CODE number 1 Activate Programming mode see 8a on page 2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x...

Page 12: ...e of numbers with examples 1 1 st digit to be input Hz 0 Pu 1 Co 8 2 2 nd digit to be input Hz 7 Pu 1 Co 4 3 3 rd digit to be input Hz 8 Pu 0 Co 3 4 4 th digit to be input Hz 4 Pu 8 Co 7 5 5 th digit...

Page 13: ...Power input max 3 5 A max 40 Watt Overvoltage protection invers polarity prot 60 Volt 1 min 30 Volt General data Life expectancy pulse capacitor 5 x 10 9 magnetic pulses Operating temperature range 4...