Summary of Contents for Qalm

Page 1: ...0...

Page 2: ...ead with a damp cloth and soapy water STEP TWO Remove the coloured plastic liner from the gel and dispose of it STEP THREE Apply the sticky gel on the device and then remove the clear plastic liner ST...

Page 3: ...e device on STEP SIX To change the programme press and release the power button STEP SEVEN Regulate the output intensity with the increase and decrease buttons STEP EIGHT After use re apply the clear...

Page 4: ...CONTROLS 10 5 2 OPERATING INSTRUCTIONS 11 6 SETTING UP AND USING QALM 12 6 1 CHARGING THE BATTERY 12 6 2 PREPARING FOR SESSION 14 6 3 TREATMENT SESSION 15 6 4 AFTER YOUR TREATMENT SESSION 16 7 CLEANIN...

Page 5: ...medical device can be safely exposed Lot Number indicates the manufacturer s batch code so that the batch or lot can be identified Humidity Limitation indicates the humidity limits to which the medic...

Page 6: ...lid foreign objects of 12 5 mm and greater The second number 2 Protected against vertically falling water drops when enclosure is tilted up to 15 Vertically falling drops shall have no harmful effects...

Page 7: ...CONTRAINDICATIONS WARNINGS CAUTIONS CONTRAINDICATIONS Do not use if you have unresolved brain or facial injuries Do not use QALM on any other areas apart from the forehead Use on the chest or neck ma...

Page 8: ...gel Trigeminal neuralgia and Ophthalmic shingles make facial nerves hypersensitive so use of QALM could be painful Caution should be used if you have a bleeding disorder as stimulation may increase b...

Page 9: ...fireplace or radiant heater or sources of high humidity such as a nebulizer or kettle as this may cause it to cease to operate correctly Caution Keep the device away from sunlight as long term exposu...

Page 10: ...educe the frequency of migraine attacks 3 2 GEL PAD ADVICE Gel pads are reusable but for single patient use In order to get the best conductivity through the gel pads always make sure they are in good...

Page 11: ...years This can be affected by very high temperatures or very low humidity 4 CONTENT The pack contains 1 x QALM unit 3 x Reusable gel pads 1 x Headband 1 x Charging cable 1 x Travel case 1 x Mirror 1...

Page 12: ...ad Note Always clean the forehead before using the device PROGRAMME CONTROL The ON OFF button is also the programme select button QALM has two pre set programmes Every time the unit is switched on the...

Page 13: ...ensity of 17mA is sufficient to have a therapeutic effect even if you feel like this intensity has become tolerated INTENSITY LEDS The unit has 34 levels of strength The strength level will be indicat...

Page 14: ...ide the device and so device warnings also apply to the battery Failure to follow these instructions could cause the lithium ion battery to leak acid become hot explode or ignite and cause injury and...

Page 15: ...reasy film on the skin 2 For first use remove one of the gel pads from its foil packaging 3 Remove the yellow plastic liner from the gel pads and apply to the rear of the QALM device 4 Remove the clea...

Page 16: ...are for single patient use Warning Ensure that QALM is switched OFF before applying and removing the device 6 3 TREATMENT SESSION 1 Press and hold the ON OFF button on the device for 3 seconds to swi...

Page 17: ...tain the stickiness of the gel When not being used the device must ALWAYS be kept in the travel case 7 CLEANING STORAGE Clean the device at least once a week by wiping with a damp cloth and a solution...

Page 18: ...of this Directive all affected products are now being marked with a crossed out wheelie bin symbol as depicted below To comply with the Directive you can return your old Qalm unit for disposal postage...

Page 19: ...ror PRODUCT WARRANTY INFORMATION This product is warranted to be free from manufacturing defects for 2 years from date of purchase This warranty is void if the product is modified or altered is subjec...

Page 20: ...connect a few minutes later the signal should feel a lot stronger Always return strength to zero or turn the device off before removing the device from the forehead If the above review has failed to r...

Page 21: ...protection Environmental specifications Operating Storage Temperature 5 to 40 Humidity 15 to 90 non condensing Atmospheric pressure 700hPa to 1060hPa Temperature 10 to 60 Humidity 15 to 75 Atmospheric...

Page 22: ...renditions pdf EC Declaration of Conformity EasyMed lnstruments Co Ltd hereby declare that an examination of the production quality assurance system has been carried out following the requirements of...

Page 23: ...22...