Programming manual V1.1

 

 

 

www.parapulser.com 

6

 

4.) 

Write down the displayed number: 
The 

Parapulser

  now  shows  with  help  of  the  LEDs  (

=

=

=

)  the 

first

  digit  of  the  up-

grade-frequency. Write down this number.

 

5.) 

Remaining 

3

 digits readout: 

rest

-key 

short

  press,  and  after  each  actuation,  write  down  the  via  LED  (

=

=

=

)  dis-

played number (

0

 – 

9

) right beside the already noted number(s). 

Repeat  this  procedure  until  a long  “

Beeep!

”-tone  signalizes,  that  all  digits  have  been 

readout. The input-mode is automatically terminated and all three LEDs (

=

=

=

) light 

up again. 

6.) 

The number sequence written down, equals the value of the pulse counter, e.g. 

3500

 

8.5   

Volume adjustment of operating-signals [

13

] and of the pulse counter [

14

–  The  volume  of  the  normal  operating  signals  and  the  beeep-tones  of  the  acoustic 

pulse counter can be adjusted independently in five levels (

1

 – 

5

).  

–  Abort volume adjustment: 

PROG

-key 

short 

press, the previous volume level remain 

unchanged and all three LEDs (

=

=

=

) light up again.  

 

Adjust volume of operating signals: 

1.) 

Activate

 Programming-mode

, see “

8

 

a)

 

on page 

2

2.) 

Activate Input-mode:

 

CODE

-key press 

2

 sec., until 

3

 “

Piep!

”-tones are audible. The input-mode is now acti-

vated: the 

red

 LED blinks 

1

x per second and in addition a Piep-tone is audible! 

3.)  2

-digit number “

13

” (operating signals) or ”

14

“ (pulse counter signals) input: 

Jump to chapter “

8.13

” on page 

11

 and follow the instructions for number entering. Af-

terwards it continues here with point 

4.)

4.) 

Select volume level: 

sel

-key 

so  often  short  press

,  until  the  desired  volume  level  (

1

  – 

5

)  is  displayed  via 

LEDs (

=

=

=

). 

5.) 

Confirm selected volume level: 

se

t

-key  short  press  to  store  the  selected  volume  level,  the  input-mode  is  terminated 

automatically and all three LEDs (

=

=

=

) light up again. 

 

8.6   

Yellow LED “ON” when consuming pulses [

15

–  On  demand,  the 

Parapulser

  shows  acoustically  and  optically,  if  a  pulse  frequency 

has been selected at which a user fee is charged, and therefore magnetic pulses are 
consumed from the pulse reservoir. An information about the user fee and consuming 
pulses you find at “

6.2

” on page 

at the

 Parapulser 

manual. 

–  Identifying feature for 

ON

-switched consuming display: 

At switch over to a puls frequency with user fee, a “

Dulip!

”-signal is audible followed 

by  a  “

Piep!

”-tone,  and  additionally  the  yellow  LED  (

=

)  flashes  at  each  consumed 

magnetic pulse. 

Summary of Contents for Parapulser

Page 1: ...M a g n e t i c P u l s e r Based on the researches of Dr R C Beck P r o g r a m m i n g V 1 1 04 2018 TAKE BACK YOUR POWER...

Page 2: ...adout 12 5 8 5 Volume adjustment of operating signals 13 and of the pulse counter 14 6 8 6 Yellow LED ON when consuming pulses 15 6 8 7 Upgrade Frequenz increase readout 16 7 8 8 Software version 17 o...

Page 3: ...arapulser switch off sel Number 0 9 memory 1 12 select HZ Frequency input activate complete rest Pulse reservoir Frequency value readout set selected number 0 9 confirm CODE Input mode e g for Code nu...

Page 4: ...into a free memory location 1 Write down the frequency value in the form of a 5 digit number e g 07843 2 Activate Programming mode see 8a on page 2 3 Select free memory location sel key press so ofte...

Page 5: ...put mode is aborted when the PROG key is shortly pressed after a jump back to a previous digit has taken place see c All so far made inputs will be rejected and the number of the selected memory locat...

Page 6: ...re audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 4 6 digit number sequence input Jump to chapter 8 13 on page 11 and follow the instr...

Page 7: ...2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 3 2 digit number 13...

Page 8: ...rade frequency increase 1 Order 6 digit upgrade CODE number at your Parapulser salesman 2 Enter the CODE number as described at 8 13 page 11 After successful CODE input the increased upgrade frequency...

Page 9: ...long Beeep tone signalizes that all digits have been readout The input mode is automatically terminated and all three LEDs light up again If the 2 digit software version has been readout the version...

Page 10: ...t of magnetic pulses Needed pulse amount number of application days x number of daily applications x pulse frequency in Hz x amount of minutes per application x 60 Example How many magnetic pulses are...

Page 11: ...8 Input of a CODE number 1 Activate Programming mode see 8a on page 2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x...

Page 12: ...e of numbers with examples 1 1 st digit to be input Hz 0 Pu 1 Co 8 2 2 nd digit to be input Hz 7 Pu 1 Co 4 3 3 rd digit to be input Hz 8 Pu 0 Co 3 4 4 th digit to be input Hz 4 Pu 8 Co 7 5 5 th digit...

Page 13: ...Power input max 3 5 A max 40 Watt Overvoltage protection invers polarity prot 60 Volt 1 min 30 Volt General data Life expectancy pulse capacitor 5 x 10 9 magnetic pulses Operating temperature range 4...