background image

                 

Programming manual V1.1

 

 

 

www.parapulser.com 

8

 

6.) 

The written numbers (e.g. “

2

” or “

10

”) equals the upgrade-frequency in [Hz]. 

 

8.8   

Software version [

17

] or serial number [

18

] readout 

Software version (

2

-digit) or serial number (

6

-digit) readout:

 

1.) 

Activate

 Programming-mode

, see “

8

 

a)

 

on page 

2

2.) 

Activate Input-mode:

 

CODE

-key press 

2

 sec., until 

3

 “

Piep!

”-tones are audible. The input-mode is now acti-

vated: the 

red

 LED blinks 

1

x per second and in addition a Piep-tone is audible! 

3.)  2

-digit number “

17

” (softw. ver.) or “

18

” (ser.-no.) input: 

Jump to chapter “

8.13

” on page 

11

 and follow the instructions for number entering. Af-

terwards it continues here with point 

4.)

4.) 

Write down the displayed numbers: 
The 

Parapulser

  now  shows  with  help  of  the  LEDs  (

=

=

=

)  the 

first

  digit  of  the  up-

grade-frequency. Write down this number. 

5.) 

Readout of remaining digits of software-version or serial number: 

rest

-key 

short

  press,  and  after  each  actuation,  write  down  the  via  LED  (

=

=

=

)  dis-

played number (

0

 – 

9

) right beside the already noted number(s). 

Repeat  this  procedure  until  a long  ”

Beeep!

“-tone  signalizes,  that  all  digits  have  been 

readout. The input-mode is automatically terminated and all three LEDs (

=

=

=

) light 

up again. 

If the 

2

-digit software version has been readout, the version you get by inserting a dot  

( . ) between the two numbers: 

 

Example

: Readout numbers: “

3

” and

 

1

”, 

à

 software version is “

3.1

”.

 

 

8.9   

Test-CODE input [

6

]

 

–  The correct input of a 

6

-digit CODE-number can be practiced unlimited with the test-

CODE “

627093

”. Thereby the risk of a CODE-lock is lowered, which will be initiated, 

when a real CODE-number is entered three times wrongly. 

–  How the numbers (

0

 – 

9

) are displayed via the LEDs (

=

=

=

), should have been un-

derstood, to be able to enter the test-CODE successfully, see “

6.1

”, on page 

at the 

Parapulser

 manual. 

–  Test-CODE  input  abort: 

PROG

-key 

as  often  short  press

,  until  all 

3

  LEDs  (

=

=

=

light up again. 

 
Test-CODE input:

 

1.) 

Activate

 Programming-mode

, see “

8

 

a)

 

on page 

2

2.)  Attention

:  For  an  explicit  identification,  that  the  test-CODE  instead  of  a  real  CODE-

number  is  being  entered,  after  each,  via 

se

t

-key  finished  digit-input,  the  yellow  LED 

(

=

) lights up for 

1

 second. 

If the yellow LED does not light up during point 

4.)

, immediately abort the CODE-input 

abbrechen (

PROG

-key 

2

 

short

 press) and start again at point 

3.)

Summary of Contents for Parapulser

Page 1: ...M a g n e t i c P u l s e r Based on the researches of Dr R C Beck P r o g r a m m i n g V 1 1 04 2018 TAKE BACK YOUR POWER...

Page 2: ...adout 12 5 8 5 Volume adjustment of operating signals 13 and of the pulse counter 14 6 8 6 Yellow LED ON when consuming pulses 15 6 8 7 Upgrade Frequenz increase readout 16 7 8 8 Software version 17 o...

Page 3: ...arapulser switch off sel Number 0 9 memory 1 12 select HZ Frequency input activate complete rest Pulse reservoir Frequency value readout set selected number 0 9 confirm CODE Input mode e g for Code nu...

Page 4: ...into a free memory location 1 Write down the frequency value in the form of a 5 digit number e g 07843 2 Activate Programming mode see 8a on page 2 3 Select free memory location sel key press so ofte...

Page 5: ...put mode is aborted when the PROG key is shortly pressed after a jump back to a previous digit has taken place see c All so far made inputs will be rejected and the number of the selected memory locat...

Page 6: ...re audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 4 6 digit number sequence input Jump to chapter 8 13 on page 11 and follow the instr...

Page 7: ...2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 3 2 digit number 13...

Page 8: ...rade frequency increase 1 Order 6 digit upgrade CODE number at your Parapulser salesman 2 Enter the CODE number as described at 8 13 page 11 After successful CODE input the increased upgrade frequency...

Page 9: ...long Beeep tone signalizes that all digits have been readout The input mode is automatically terminated and all three LEDs light up again If the 2 digit software version has been readout the version...

Page 10: ...t of magnetic pulses Needed pulse amount number of application days x number of daily applications x pulse frequency in Hz x amount of minutes per application x 60 Example How many magnetic pulses are...

Page 11: ...8 Input of a CODE number 1 Activate Programming mode see 8a on page 2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x...

Page 12: ...e of numbers with examples 1 1 st digit to be input Hz 0 Pu 1 Co 8 2 2 nd digit to be input Hz 7 Pu 1 Co 4 3 3 rd digit to be input Hz 8 Pu 0 Co 3 4 4 th digit to be input Hz 4 Pu 8 Co 7 5 5 th digit...

Page 13: ...Power input max 3 5 A max 40 Watt Overvoltage protection invers polarity prot 60 Volt 1 min 30 Volt General data Life expectancy pulse capacitor 5 x 10 9 magnetic pulses Operating temperature range 4...

Reviews: