M a g n e t i c   P u l s e r

  

(Based on the researches of Dr. R. C. Beck)

 

 

 

P r o g r a m m i n g  

 

V 1.1  •  04. 2018 

 
 

TAKE BACK YOUR POWER

 

Summary of Contents for Parapulser

Page 1: ...M a g n e t i c P u l s e r Based on the researches of Dr R C Beck P r o g r a m m i n g V 1 1 04 2018 TAKE BACK YOUR POWER...

Page 2: ...adout 12 5 8 5 Volume adjustment of operating signals 13 and of the pulse counter 14 6 8 6 Yellow LED ON when consuming pulses 15 6 8 7 Upgrade Frequenz increase readout 16 7 8 8 Software version 17 o...

Page 3: ...arapulser switch off sel Number 0 9 memory 1 12 select HZ Frequency input activate complete rest Pulse reservoir Frequency value readout set selected number 0 9 confirm CODE Input mode e g for Code nu...

Page 4: ...into a free memory location 1 Write down the frequency value in the form of a 5 digit number e g 07843 2 Activate Programming mode see 8a on page 2 3 Select free memory location sel key press so ofte...

Page 5: ...put mode is aborted when the PROG key is shortly pressed after a jump back to a previous digit has taken place see c All so far made inputs will be rejected and the number of the selected memory locat...

Page 6: ...re audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 4 6 digit number sequence input Jump to chapter 8 13 on page 11 and follow the instr...

Page 7: ...2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x per second and in addition a Piep tone is audible 3 2 digit number 13...

Page 8: ...rade frequency increase 1 Order 6 digit upgrade CODE number at your Parapulser salesman 2 Enter the CODE number as described at 8 13 page 11 After successful CODE input the increased upgrade frequency...

Page 9: ...long Beeep tone signalizes that all digits have been readout The input mode is automatically terminated and all three LEDs light up again If the 2 digit software version has been readout the version...

Page 10: ...t of magnetic pulses Needed pulse amount number of application days x number of daily applications x pulse frequency in Hz x amount of minutes per application x 60 Example How many magnetic pulses are...

Page 11: ...8 Input of a CODE number 1 Activate Programming mode see 8a on page 2 2 Activate Input mode CODE key press 2 sec until 3 Piep tones are audible The input mode is now acti vated the red LED blinks 1x...

Page 12: ...e of numbers with examples 1 1 st digit to be input Hz 0 Pu 1 Co 8 2 2 nd digit to be input Hz 7 Pu 1 Co 4 3 3 rd digit to be input Hz 8 Pu 0 Co 3 4 4 th digit to be input Hz 4 Pu 8 Co 7 5 5 th digit...

Page 13: ...Power input max 3 5 A max 40 Watt Overvoltage protection invers polarity prot 60 Volt 1 min 30 Volt General data Life expectancy pulse capacitor 5 x 10 9 magnetic pulses Operating temperature range 4...