Product Overview ............................................................... 1

 

Product Contents ............................................................... 2 
Adjusting the Cap ……………………….………………………….……. 2 
Connecting to the Cap ...................................................3 
Cap Firmware……………………………………………………………………3 
Performing a Treatment ................................................. 4 
User Control  ........................................................................ 4 
Charging the Cap ..............................................................5 
Menu Tour ...............................................................................5 
Cleaning and Travel .......................................................... 7 
Troubleshooting .................................................................. 7 
Learn More ........................................................................... 10 
Appendices………………………………………………………………………14+ 

 

 

 

 

 

 

 

 

Product Overview

 

2. 

 

 

The REVIAN RED System is to be used in male and female 

patients with androgenetic alopecia in ages 18 and 

above. It is a non-invasive, hands-free, over-the counter 

medical device operated via mobile app to promote hair 

growth

REVIAN  RED  is intended for a daily 10-minute 

treatment. A treatment can be paused after it is initiated, 

the remaining treatment time must be used prior to the 

initiation of another treatment.

 

 

Indications for Use:  REVIAN  RED  is indicated to treat 

androgenetic alopecia and promote hair growth in males 

who have Norwood-Hamilton Classifications  of IIa to V 

patterns of hair loss; and to treat androgenetic alopecia 

and promote hair growth in females who have Ludwig-

Savin Scale I-1 to I-4, II-1, II-2, or frontal patterns of hair 

loss, both with Fitzpatrick Skin Types I - IV. 

 

Contraindications for Use:

 

REVIAN RED has no known 

contraindications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for RED 101

Page 1: ...he counter medical device operated via mobile app to promote hair growth REVIAN RED is intended for a daily 10 minute treatment A treatment can be paused after it is initiated the remaining treatment...

Page 2: ...tandard and back 10mm headliners installed as illustrated below The Cap should not be loose enough that it falls off the head with ease nor should it fit too tightly A proper fitting Cap is an importa...

Page 3: ...s when the Cap is properly placed on your head Place the Cap on your head to activate the sensor or put your finger over the sensor located in the forehead area of the cap Press the CONNECT YOUR CAP b...

Page 4: ...again on your head and it will automatically pick up where it left off Only a single 10 minute treatment can be initiated daily Time remaining will be displayed on the mobile app screen Another treatm...

Page 5: ...ht will softly flash every 4 seconds When the cap is charging the app is not connected and will not provide a battery level To determine the battery level disconnect the charging cable from the cap an...

Page 6: ...during support tickets to help troubleshoot any issues you may be having with the app SUPPORT In the Troubleshooting section you can find answers to commonly asked questions and troubleshoot issues If...

Page 7: ...Messages and sound signals during use The mobile app will display messages on occasion These will appear as direct messages or icons in the mobile app App Messages Check Bluetooth This message appear...

Page 8: ...ice and not the Cap Check mobile device settings and ensure device isn t already paired with another device The mobile app is not scanning for the Cap Force the mobile app to scan for the Cap by tappi...

Page 9: ...revian com or on the website at revian com support PROBLEM POSSIBLE CAUSE SOLUTION The mobile app will not download firmware or software updates The cloud server is unavailable The device software is...

Page 10: ...te blue The charging cable connector will illuminate blue always when connected to AC power The battery should be charged from a depleted state to a full charge within 4 hours The battery will have en...

Page 11: ...of cleaning agents or solvents are not recommended and may damage the REVIAN RED Cap The battery is rechargeable but not intended as a user replaceable part Use the Cap only as intended and described...

Page 12: ...everse hair loss The approximate size of the Cap is Height 15 87 cm 6 25 in x Width 20 cm 7 87 in x Length 22 86 cm 9 in Weight 155 g 0 34lbs How is the REVIAN RED Cap shipped After order completion t...

Page 13: ...d I attach headliners The recommended headliners not only ensure proper fit of the Cap but they also provide additional comfort and help maintain cleanliness Is this a use it or lose it treatment plan...

Page 14: ...Compliance Electromagnetic Environment Guidance RF emissions CISPR 11 Group 1 REVIAN RED uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cau...

Page 15: ...quality should be that of a typical commercial hospital or home healthcare environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth PASS Mains power quality should be that of a typic...

Page 16: ...manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site surveya should be less than the compliance lev...

Page 17: ...as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 k...

Page 18: ...een the REVIAN mobile application running on an iOS or Android operating system and REVIAN cloud services as well as between the REVIAN app and the REVIAN RED Cap Figure E1 Communications of treatment...

Page 19: ...energy and if not used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular instal...