QUICKGUIDE
SIGMA
2
SYNERGIC
UK
501
1
3719 F
Selecting welding program
Press and hold (14A) to open for selecting welding program. A “P” is displayed in (12) and a figure
is displayed in (13), referring to the list of welding programs (enclosure 50113742). The active
welding program is marked with “•”. Select welding program by turning (14). Press (14A) briefly to
accept choice.
Recall factory settings
After long press on (14A), press and hold (19) until the list of welding programs is closed.
Setting welding process
Press and hold (14A) to open for setting the welding process. Choose parameter by turning (14). Set the chosen
value by turning (15). To close this function, press (15A) briefly.
MIG parameters
* F33, F34, F35 and F36 are only adjustable when a synergic MIG welding programme is chosen.
* F32 (softstart) is off when “----” is displayed.
* F33 (hotstart) is to be set in % of the set welding current.
* F52
Cable compensation (calibration of resistance in welding hose)
* F71 Reduction of voltage trim (0-50%)
* F72 Reduction of current setting (0-25%)
Set welding current (A)
DUO Plus™ parameters
(not manual)
When (18) is activated, the operator is also
allowed access to the following DUO Plus™
parameters:
A
MMA (elektrode) parameters
When the MMA welding programme is
chosen, the operator is allowed access to
the following parameters only:
t
Short circuit
Set welding
current (A)
Set
welding
current
(A)
F21
DUO Plus
TM
time (s)
Pause time
(s)
F12
t
F11
%
F20
DUO Plus
TM
efficiency rate 0-50%
of set welding current (A)
%
F11
Hotstart
(25%)
F12
Hotstart time (0,5 sec.)
F13
Arc force
(25%)
F31
Pre-gas
(0,2 sec.)
F32
Softstart
(1,0 m/min.)
F33
Hotstart
(25%)
F34
Hotstart time (0,5 sec.)
F35
Slope
(0,2 sec.)
F36
Stop amp
(50 %)
F37
Burn-Back
(5 (0-30))
F38
Post-gas
(3,0 sec.)
F39
Spot time
(0,0 sec.)
F40
Stop Amp time (0,0 sec.)
F13
Figure 1
t
A