background image

 

- 30 - 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Migali

 Industries,  Inc.   

      Trusted  Since  1955  
 
      516 Lansdowne Ave  
      Camden, NJ 08104 
      Service Call: 800.852.5292 
      Service Email: [email protected] 

Summary of Contents for C-RB24-LP

Page 1: ...ar Broilers Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models C RB24 NG LP...

Page 2: ...anual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The...

Page 3: ...2 Gas Radiant Countertop Char Broilers Installation Operation and Maintenance Guide Contents 1 Safety Protection 3 2 Brief Introduction 4 3 Manufacturer s Authority and Responsibility 4...

Page 4: ...ion Please make sure that the operator is an authorized and licensed technician before you allow him her to install and operate the products Be sure to strictly follow this instruction guide during in...

Page 5: ...with appropriate instructions and sufficient safety 2 Brief Introduction The product is a series of gas char broilers in our company production which is novel designed reasonable structured convenient...

Page 6: ...eters using this product Incorrectly or irrationally using the product by untrained personnel Not obey the local law using this product Be repaired or changed by unauthorized technicians Use the spare...

Page 7: ...6 C RB36 NG LP...

Page 8: ...7 C RB48 NG LP...

Page 9: ...l Natural Gas 4 35 000 70 000 36 L P Gas 10 35 000 70 000 50 C RB36 NG LP 3 pieces Independen t control Natural Gas 4 35 000 105 000 36 L P Gas 10 35 000 105 000 50 C RB48 NG LP 4 pieces Independen t...

Page 10: ...23 1 NFPA 54 the National Gas Installation Code CSA B149 1 or the L P Gas Installation Code CSA B149 2 as applicable The appliance individual shutoff valve must be disconnected from the gas supply pip...

Page 11: ...e matched cooking fume exhauster according to the local regulations Important Installation and ventilation laws and codes are very different you should state and comply with all codes of the National...

Page 12: ...e in front of the equipment to take apart the control panel All major parts in addition to the burner remove from the front intake tube It may be necessary to adjust the balance of air input by author...

Page 13: ...will need to adjust gas pressure regulating valve or contact gas supplier to bargain Fig 1 Unplug pressure gauge after you accomplish pressure testing then install needle type pressure joint screw ar...

Page 14: ...precautions immediately Immediately turn off the main gas valve extinguish all heat and flames and call 911 Safety information can be obtained from your local gas suppliers When using this equipment...

Page 15: ...manufacturer has the right not to provide warranty service Steel cutting producers used to manufacture with sharp edges The manufacturer has dealt with these sharp edges during production however we...

Page 16: ...he pipe Wait a minute the pilot light will be lighted after the gas extinguished Tips You can use a screwdriver to adjust the height of the flame Fig 3 8 2 Lighting the main burner Revolve the main fi...

Page 17: ...wise to 0 Fig 1 so that extinguish flame of the main burner but the pilot light still works After turning off the equipment the main fire should be stop more than 5 minutes before next using 8 4 Stove...

Page 18: ...catch tray Fig 5 Fig 6 Fig 7 8 5 Exchange main fire nozzle to switch gas source Remove control panel grate and heat storage plate remove the pilot light head and bottom tightening screw of the end of...

Page 19: ...the equipment will not get loose in the process of moving and translation Reinstall control panel Caution Each burner damper has been adjusted before delivery once air input normal use without adjustm...

Page 20: ...g time clean the surface by wiping it with a soft cloth and place it in a well ventilated area Comprehensively check the equipment at least once every year by authorized and licensed technicians The p...

Page 21: ...radiants in order to prevent possible burns 1 Take out grates and radiants 2 Clean up grease and other impurity on grates with a wire brush 3 Clean grid slot with a scraper 4 Grates coated with food...

Page 22: ...nt body until the equipment cools down Clean grease and other crumbs Reinstall after cleaning and daubing lubricants Warning if the catch tray is permitted to fill too high should be cleaned Per use 1...

Page 23: ...of the pilot light Close gas and heard a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3...

Page 24: ...op using and contact technicians to check and repair Safety first turn off the power and gas supply before maintenance 11 Spare Parts The use of parts provided by other companies our company has the r...

Page 25: ...24 Fig 11 Table 4 No Matters Code Component name Qty Dimensions mm Model Remark...

Page 26: ...anized American outside six corner with pad tapping 24 ST4 8 12 5 C RB24 NG LP 3 6 NG LP 48 NG LP 6 21105001035 Control panel 1 605 185 C RB24 NG LP 21105002028 905 185 C RB36 NG LP 21105002028 1205 1...

Page 27: ...B24 NG LP 3 C RB36 NG LP 4 C RB48 NG LP 16 21205001001 countertop 1 610 700 218 C RB24 NG LP 21205002001 910 700 218 C RB36 NG LP 21205003001 1210 700 218 C RB48 NG LP 17 301020006 grates 4 150 525 22...

Page 28: ...26 803 648 C RB36 NG LP 301070003 48 counterto p char broiler intake tube 26 1113 648 C RB48 NG LP 24 21205001002 surround 1 600 640 203 C RB24 NG LP 21205002002 900 640 203 C RB36 NG LP 21205003002 1...

Page 29: ...ns to assure interface tightness 2 Screw the hex nut Fig 12 before connect air intake ensure gas mark Fig 13 on the plastic core whether match with connected gas source if not then pull out the plasti...

Page 30: ...nforms to NSF ANSI STD 4 S A N I TAT I ON Our products have the advantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length...

Page 31: ...30 Migali Industries Inc Trusted Since 1955 516 Lansdowne Ave Camden NJ 08104 Service Call 800 852 5292 Service Email warranty mgiali com...