- 18 -
the gas source, exchange the corresponding pressure maintaining valve
which installed on air intake. See 2 in P17.
8.6
、
Adjust air input
Remove control panel, unscrew damper solid screw(Fig.9), revolve
damper left to right (Fig.10), meanwhile, observe flame and adjust an
appropriate opening degree. Then screw damper solid screw, make sure the
equipment will not get loose in the process of moving and translation.
Reinstall control panel.
Caution: Each burner damper has been adjusted before delivery
(once air input), normal use without adjustment but only switching gas.
Adjust only by authorized and licensed technicians.
Fig.8 Fig.9 Fig.10
9. Cleaning and Maintenance
Do not use any abrasive or flammable detergent to wipe;
Do not hose down, immerse or pressure wash any part of the char
broiler, excluding the catch tray;
Do not use abrasive cleaning matters to wash, even not use