Note for test institutes
*
Test programme in accordance with EN 60456 and energy label with
Directive 1061/2010
With the
PowerWash
washing technique, during the heating phase, the temper-
ature measured by the sensor in the suds container is higher than the actual
temperature of the laundry.
The temperature measured at the sensor
does not
reflect the temperature of
the laundry.