Plumbing
Connect the water supply hose (the
hose marked blue) to the cold water
valve.
Turn on the valve and check for leaks.
The water pressure must be within
15-145 psi (1-10 bar). If the water pres-
sure is greater than 145 psi
(10 bar), a pressure reducer must be
installed. If the water pressure is below
15 psi (1 bar), insufficient water may be
available for a complete fill.
The water supply hose is equipped with
a filter; please do not remove this filter.
Connection to the drain sys-
tem.
The 5 ft. (1.5m) drain hose may be con-
nected as follows:
1. Directly into a sink:
hook the hose
over the edge of the sink and secure
it firmly (e.g. by tying the hose to the
water faucet).
2. To a stand pipe
: place the drain
hose
into a 1
1
/
2
“ (38 mm) stand pipe and
firmly secure it.
3. To a floor drain
: The machine is
equipped with an airgap/anti-siphon-
ing system so that no minimum drain
height is required.
– The machine drains using a pump
with a maximum delivery height of 4
ft. (1.2 m).
– Make sure there are no kinks in the
drain hose.
– If desired, the drain hose may be ex-
tended to 15 ft. (4.5 m) maximum.
Plumbing
33