en - Installation notes
*INSTALLATION*
30
A vented drainage system is vital for unimpeded drainage.
If several machines are connected to a single drain pipe, this
should be sufficiently large to allow all machines to drain simultan-
eously.
The appropriate Miele installation kit (mat. no.: 05 238 090) is avail-
able to order from the Miele Customer Service Department or your
Miele dealer for venting an HT DN 70 pipe.
If the slope for drainage is extremely steep, the piping must be ven-
ted to prevent formation of a vacuum in the machine’s drainage
system.
Slow or obstructed drainage or a backup of water in the drum as a
result of undersized pipework can result in faults occurring during
programmes, which will result in fault messages appearing in the dis-
play.
Outflowing suds can be as hot as 95 °C. Danger of burning!
Avoid direct contact.
Dispensing pump connections
Up to 12 dispensing pumps can be connected to the washing ma-
chine.
Dispensing pump connections on the back of the machine
Connections
1
and
2
are provided for viscous agents and can also be
used for high-pressure dispensing systems with water injection. The
dispensing systems must be fitted with a separate drinking water
safety mechanism in accordance with Regulation 4 of The Water Sup-
ply (Water Fittings) Regulations 1999 EN 61770 and EN 1717. The
maximum flow rate is 1500 ml/min with a maximum flow pressure of
300 kPa.
These connectors are sealed and need to be drilled open using a
8 mm drill bit before connecting.
Summary of Contents for PWM 916 EL
Page 2: ...2 de 4 en 25 fr 45 es 67 ru 88 it 110 ...
Page 18: ...de Aufstellung INSTALLATION 18 Standard Maßangaben in Millimeter Standfuß ...
Page 19: ...de Aufstellung INSTALLATION 19 Sockel Maßangaben in Millimeter ...
Page 38: ...en Installation INSTALLATION 38 Standard Dimensions in mm Machine foot ...
Page 39: ...en Installation INSTALLATION 39 Plinth Dimensions in mm ...
Page 59: ...fr Installation INSTALLATION 59 Par défaut Dimensions en millimètres Pied ...
Page 60: ...fr Installation INSTALLATION 60 Socle Dimensions en millimètres ...
Page 81: ...es Emplazamiento INSTALLATION 81 Estándar Medidas en milímetros Base de apoyo ...
Page 82: ...es Emplazamiento INSTALLATION 82 Zócalo Medidas en milímetros ...
Page 103: ...ru Установка INSTALLATION 103 Стандарт Размеры в мм Ножка ...
Page 104: ...ru Установка INSTALLATION 104 Цоколь Размеры в мм ...
Page 124: ...it Posizionamento INSTALLATION 124 Standard Misure in millimetri Piedino ...
Page 125: ...it Posizionamento INSTALLATION 125 Base Misure in millimetri ...