Connecting the drain hose to a sink drain outlet

 

The drain hose can be connected securely to a suitable sink drain 
outlet.  

 

 

 

If required, the hose can be extended to a length of up to 16.4 ft (5 m). 
Accessories are available from your Miele dealer or Miele Technical 
Service. 

For a drain height of more than 3' 3 3/8" (1 m) up to a max. of 1.6 m), 
a replacement drain pump is available from Miele Technical Service or 
your Miele dealer. 

Equipotential bonding and grounding 

If necessary, an equipotential bond with good contact connection must 
be provided in accordance with all appropriate national and local 
regulations. 

Material for equipotential bonding and grounding must be provided on 
site or using a kit available from Miele Technical Service. 

Peak load/Energy management 

The machine can be connected to a peak-load or energy 
management system using an optional kit.  

When the peak-load function is activated, the heating is deactivated. 
A message appears in the display to inform you of this. 

Liquid dispensing connection 

External liquid dispenser pumps with a “container empty” indicator can 
be used to dispense liquid detergents.  

The dispenser pumps can only be programmed with MDU. 

It is particularly important to follow the manufacturer’s instructions 
when using a combination of detergents, additives, and special-
purpose products. 

Payment system 

This washing machine can be equipped with a single-machine 
payment system as an optional accessory using an optional kit 
(XCI box).  

The programming required for connecting a payment system can be 
carried out during the initial commissioning process. After initial 
commissioning, changes may only be carried out by your Miele dealer 
or Miele Technical Service. 

Interface 

The machine can be retrofitted with an XKM 3200 WL PLT 
communication module.  

This module can be used as a WiFi or LAN interface. 

The LAN interface provided via the module complies with SELV 
(Safety Extra Low Voltage) in accordance with EN 60950. Connected 
appliances must also comply with SELV. The LAN connection uses a 
RJ45 connector in accordance with EIA/TIA 568-B. 

Installation 

The machine must be installed on a perfectly smooth, level, and firm 
surface which is able to withstand the quoted loads.  

The floor load created by the machine is concentrated and transferred 
to the installation footprint via the machine feet. 

The machine should be leveled in both directions with the aid of the 
adjustable feet. 

Plinth installation 

The washing machine can be installed on a machine plinth (open or 
box plinth, available as an optional Miele accessory) or on a concrete 
plinth to be provided on site. 

The quality of the concrete and its strength must be assessed 
according to the machine load. Ensure that any raised concrete plinth 
is adequately bonded to the floor below. 

If the washing machine is installed on a concrete or masonry plinth, it 
must be secured using the anchors supplied with the machine. 
Otherwise, there is a risk of the washing machine moving about during 
spinning and falling off the plinth. 
 

 

 

The anchors provided can be used to bolt the machine to the floor by 
both front feet. The fasteners provided are intended for use in bolting 
the machine to a concrete floor. 

Washer-dryer stack 

The washing machine can be installed as a washer-dryer stack 
together with a Miele Tumble Dryer. A stacking kit (optional 
accessory) is required for this. 

Installation of the stacking kit must be performed by Miele Technical 
Service or an authorized Miele service technician.

 

Summary of Contents for PWM 908 DP

Page 1: ...hing Machine PWM 908 DV DP Always read the operating and installation instructions before setting up installing and commissioning the machine This prevents both personal injury and damage to the machine en US 11 282 580 00 ...

Page 2: ...20 1348 proservice mieleusa com Legend Connection required Connection optional or required depending on model DV Drain valve KW Cold water connection AW Drain connection DP Drain pump B Machine anchoring PA Equipotential bonding and grounding DOS Dispenser connection SLA Peak load connection EL Electrical connection UG Closed plinth F Machine feet adjustable UO Open plinth KG Payment system APCL W...

Page 3: ...PWM 908 en US 11 282 580 00 3 Machine dimensions F F F F F F F F EL KGA SLA XKM DP DV KW WW DOS PA ...

Page 4: ...PWM 908 en US 4 11 282 580 00 Installation EL WW KW KG DV DP KG WW KW EL DP DV KGA SLA EL WW KW KG DP UO UG DV UO UG KG WW KW EL DP DV KGA SLA PA PA ...

Page 5: ...PWM 908 en US 11 282 580 00 5 Washer dryer stack F F EL WW KW DP DV EL WW KW F F APCL APCL KGA SLA DV PA ...

Page 6: ...PWM 908 en US 6 11 282 580 00 Installation 305 145 5 145 5 681 1031 B B B B BS B B 305 145 5 145 5 305 1031 B B 148 148 305 148 148 BS ...

Page 7: ...PWM 908 en US 11 282 580 00 7 Installation UO UG B B UO UG B B UO UG B B B B UO UG B B B B ...

Page 8: ...min cross section mm 3 x 1 5 3 x 1 5 Non standard voltages MAR 400 440 480 Marine 3 AC 400 440 480V Frequency Hz 50 60 Total rated load kW 3 6 4 23 5 0 Fuse rating B trip rating according to EN 60898 A 3 x 16 Power cord min cross section mm 4 x 1 5 Wire without plug Wire length inch mm 78 3 4 2 000 Non standard voltage MAR 230 Marine 3 AC 230 V Frequency Hz 50 60 Total rated load kW 4 4 Fuse ratin...

Page 9: ...to EN 60898 A 3 x 10 3 x 10 Power cord min cross section mm 5 x 1 5 5 x 1 5 Wire without plug Wire length inch mm 78 3 4 2 000 78 3 4 2 000 Standard voltage B only 2N AC 400 V 2N AC 400 V Frequency Hz 50 50 Total rated load kW 5 5 5 5 Fuse rating B trip rating according to EN 60898 A 2 x 16 2 x 16 Power cord min cross section mm 4 x 2 5 4 x 2 5 Wire without plug Wire length inch mm 78 3 4 2 000 78...

Page 10: ...rating A 2 x 30 Power cord min cross section 3 x AWG10 Wire with plug Wire length inch mm 78 3 4 2000 Cold water KW Permissible water flow pressure PSI kPa 1 45 14 5 100 1 000 1 45 14 5 100 1 000 Required flow rate cold water connection only gal min l min 2 9 11 2 9 11 Required flow rate with additional hot water connection gal min l min 2 6 10 2 6 10 Average water consumption 60 C standard progra...

Page 11: ...spensing DOS Connection for liquid dispensing agents Max no of dispenser pumps No 6 6 XCI box LG interface Installation on machine feet F No of machine feet No 4 4 Machine foot height adjustable with thread inch mm 5 16 8 5 16 8 Machine foot diameter inch mm 10 5 40 10 5 40 Anchoring B Standard floor anchoring Floor anchor kit for 2 machine feet with anchors Wood screws according to DIN 571 inch m...

Page 12: ...16 23 13 16 900 605 Installation dimensions Min side gap inch mm 13 16 20 13 16 20 Recommended side gap washer dryer stack inch mm 11 13 16 300 11 13 16 300 Min distance to opposite wall from front of machine inch mm 37 3 8 950 37 3 8 950 Recommended distance to opposite wall from front of machine inch mm 43 5 16 1 100 43 5 16 1 100 Weights and floor loads Machine weight net weight lb kg 227 103 2...

Page 13: ...nts of the electric utility company If converting the machine to an alternative voltage follow the instructions in the wiring diagram Conversion must be performed by Miele Technical Service or by an authorized service technician The heater rating must also be adapted The machine must not be connected to devices such as timers which would switch it off automatically References to cable cross sectio...

Page 14: ...ges may only be carried out by your Miele dealer or Miele Technical Service Interface The machine can be retrofitted with an XKM 3200 WL PLT communication module This module can be used as a WiFi or LAN interface The LAN interface provided via the module complies with SELV Safety Extra Low Voltage in accordance with EN 60950 Connected appliances must also comply with SELV The LAN connection uses a...

Reviews: