PWM 908
en-US
= standard,
= optional, + = only on request, - not available
10
11 282 580/00
Technical data
PWM 908 DV
PWM 908 DP
Alternative voltage (convertible)
2N AC 400 V
2N AC 400 V
Total rated load
kW
5.5
5.5
Fuse rating (B trip rating according to EN 60898)
A
2 x 16
2 x 16
Power cord min. cross-section
mm²
4 x 1.5
4 x 1.5
Standard voltage (AUS only)
1N AC 230 V
1N AC 230 V
Frequency
Hz
50
50
Total rated load
kW
5.5
5.5
Fuse rating
A
1 x 25
1 x 25
Power cord min. cross-section
mm²
3 x 2.5
3 x 2.5
Wire without plug
Wire length
inch (mm)
78 3/4" (2,000)
78 3/4" (2,000)
Standard voltage (AUS only)
-
1N AC 230 V
Frequency
Hz
-
50
Total rated load
kW
-
2.85
Fuse rating
A
-
1 x 16
Power cord min. cross-section
mm²
-
3 x 1.5
Wire with plug
-
Wire length
inch (mm)
-
78 3/4" (2,000)
Alternative voltage (convertible)
-
1N AC 230 V
Frequency
Hz
-
50
Total rated load
kW
-
5.5
Fuse rating
A
-
1 x 25
Power cord min. cross-section
mm²
-
3 x 2.5
Standard voltage for CDN & USA
-
2 AC 208-240 V
Frequency
Hz
-
60
Total rated load
kW
-
4.0
– 5.2
Fuse rating
A
-
2 x 30
Power cord min. cross-section
-
3 x AWG10
Wire with plug
-
Wire length
inch (mm)
-
78 3/4" 2000
C o l d w a t e r ( K W )
Permissible water flow pressure
PSI (kPa)
1.45
– 14.5 (100 – 1,000) 1.45 – 14.5 (100 – 1,000)
Required flow rate (cold water connection only)
gal/min (l/min) 2.9 (11)
2.9 (11)
Required flow rate (with additional hot water connection)
gal/min (l/min) 2.6 (10)
2.6 (10)
Average water consumption (60°C standard programme)
gal/h (l/h)
10.5 (40)
10.5 (40)
Connection to be provided on site, external thread according to DIN 44991 (flat seal)
Inches
¾"
¾"
Connection hose ½" with ¾" threaded union
Connection hose length
inch (mm)
61 (1,550)
61 (1,550)
H o t w a t e r ( W W )
Max. water intake temperature
°F (°C)
158 (70)
158 (70)
Permissible water flow pressure
PSI (kPa)
1.45
– 14.5 (100 – 1,000) 1.45 – 14.5 (100 – 1,000)
Required flow rate
gal/min (l/min) 2.9 (11)
2.9 (11)
Average water consumption (60°C standard programme)
gal/h (l/h)
3.4 (13)
3.4 (13)
Connection to be provided on site, external thread according to DIN 44991 (flat seal)
Inches
¾"
¾"
Connection hose ½" with ¾" threaded union
Connection hose length
inch (mm)
61 (1,550)
61 (1,550)
D r a i n v a l v e ( D V )
Connector (ext. diameter)
inch (mm)
3 (75) /DN70
-
Max. drainage temperature
°F (°C)
194 (90)
Max. transient flow rate
gal/min (l/min) 16 (62)
-