Installation and planning notes  

Installation requirements 

The machine should only be connected to a power supply provided in 
accordance with all appropriate local and national legislation and 
regulations. 

In addition, all regulations issued by the appropriate utilities as well as 
standards relating to occupational safety and all applicable valid 
regulations and technical standards must be observed. 

Transportation and site access 

The washing machine must not be moved without the shipping struts 
in place. Keep the struts in a safe place. They must be refitted if the 
machine is to be moved again (e.g., when moving house). 

General operating conditions 

Ambient temperature in installation room: +36°F to +95°F (+2°C to 
+35°C). 

Depending on the nature of the installation site, sound emissions and 
vibration may occur. Miele recommends having the installation site 
inspected and seeking the advice of a professional in instances where 
increased noise may cause a nuisance. 

Electrical connection 

Depending on the model, the machine will be delivered with a wire 
with/without a plug. 

The machine may only be connected to an electrical system that 
conforms to national and local codes and regulations. This connection 
must be made by a qualified electrician. 

The data tag indicates the nominal power consumption and the 
appropriate fuse rating. Compare the specifications on the data tag 
with those of the electrical power supply. 

The machine can either be hard-wired or connected using a plug-and-
socket connection in accordance with IEC 60309-1. Miele always 
recommends connecting the machine via a plug and socket so that 
electrical safety checks can be carried out easily (during repair or 
service work, for example). 

If the machine is hard-wired, a dual circuit breaker must be provided 
on site. When switched off, there must be an all-pole contact gap of at 
least 3 mm in the isolator switch (including circuit breakers, breakers, 
and relays according to IEC/EN 60947).  

The plug connector or isolator switch should be easily accessible at all 
times. If the machine is disconnected from the electricity supply, the 
isolator must be lockable or the point of disconnection must be 
monitored at all times. 

New connections, modifications to the system, or servicing of the 
ground conductor, including determining the correct fuse rating, must 
be carried out by a qualified electrician, as they are familiar with the 
pertinent regulations and the specific requirements of the electric 
utility company. 

If converting the machine to an alternative voltage, follow the 
instructions in the wiring diagram. Conversion must be performed 
by Miele Technical Service or by an authorized service technician. 
The heater rating must also be adapted. 

The machine must not be connected to devices such as timers which 
would switch it off automatically. 

References to cable cross-sections in the technical data refer only to 
the required power cord. Please consult relevant local and national 
regulations when calculating any other wire gauges.

Cold water connection

 

The washing machine should be connected to a domestic water 
supply in accordance with current local and national safety 
regulations.  

Connection to the water supply should be carried out by a qualified 
plumber using a stopcock with a threaded union. If a stopcock is not 
available, the qualified plumber should connect the machine to the 
domestic water supply. 

A suitable connection hose with a threaded union is supplied with the 
machine. 

Longer hoses 8' 2 1/2" or 13' 1 1/2" (2.5 m or 4.0 m) in length are 
available from Miele Technical Service or from your Miele dealer as 
accessories. 

Hot water connection 

The same connection requirements as for cold water also apply to hot 
water (max. 158°F/70°C). 

A suitable connection hose with a threaded union is supplied with the 
machine. 

The hot water connection appliance also requires a cold water 
connection. 

In the event that hot water is not available on site, connection of the 
second hose must be made to a cold water supply. 

Alternatively, the hot water connection should be blocked using the 
enclosed blind stopper and the machine controls set to cold water 
intake.  

The required amount of hot water should be added to the cold water 
volume. 

Drain valve (depending on model) 

The machine is drained using a motorized drain valve. It can be 
connected directly to the on-site drainage system (without a siphon) or 
via a floor drain (gully with odor trap). 

A vented drainage system is vital for unimpeded drainage. If on-site 
venting is insufficient, a vent kit (mat. no. 05 239 540) is available from 
your Miele dealer or Miele Technical Service. 

If several machines are connected to a single drain pipe, this should 
be sufficiently large to allow all machines to drain simultaneously. 

Drain pump (depending on model) 

The suds are drained through a drain pump with a 1 m delivery head. 
For the water to drain freely, the hose must be installed free of kinks.  

 

Drainage options: 

1. Connected securely to a plastic drain pipe with a rubber nipple 
(there is no need to use a siphon). 

2. Connected securely to a sink with a plastic nipple. 

3. Connected securely to a floor drain. 

Summary of Contents for PWM 908 DP

Page 1: ...hing Machine PWM 908 DV DP Always read the operating and installation instructions before setting up installing and commissioning the machine This prevents both personal injury and damage to the machine en US 11 282 580 00 ...

Page 2: ...20 1348 proservice mieleusa com Legend Connection required Connection optional or required depending on model DV Drain valve KW Cold water connection AW Drain connection DP Drain pump B Machine anchoring PA Equipotential bonding and grounding DOS Dispenser connection SLA Peak load connection EL Electrical connection UG Closed plinth F Machine feet adjustable UO Open plinth KG Payment system APCL W...

Page 3: ...PWM 908 en US 11 282 580 00 3 Machine dimensions F F F F F F F F EL KGA SLA XKM DP DV KW WW DOS PA ...

Page 4: ...PWM 908 en US 4 11 282 580 00 Installation EL WW KW KG DV DP KG WW KW EL DP DV KGA SLA EL WW KW KG DP UO UG DV UO UG KG WW KW EL DP DV KGA SLA PA PA ...

Page 5: ...PWM 908 en US 11 282 580 00 5 Washer dryer stack F F EL WW KW DP DV EL WW KW F F APCL APCL KGA SLA DV PA ...

Page 6: ...PWM 908 en US 6 11 282 580 00 Installation 305 145 5 145 5 681 1031 B B B B BS B B 305 145 5 145 5 305 1031 B B 148 148 305 148 148 BS ...

Page 7: ...PWM 908 en US 11 282 580 00 7 Installation UO UG B B UO UG B B UO UG B B B B UO UG B B B B ...

Page 8: ...min cross section mm 3 x 1 5 3 x 1 5 Non standard voltages MAR 400 440 480 Marine 3 AC 400 440 480V Frequency Hz 50 60 Total rated load kW 3 6 4 23 5 0 Fuse rating B trip rating according to EN 60898 A 3 x 16 Power cord min cross section mm 4 x 1 5 Wire without plug Wire length inch mm 78 3 4 2 000 Non standard voltage MAR 230 Marine 3 AC 230 V Frequency Hz 50 60 Total rated load kW 4 4 Fuse ratin...

Page 9: ...to EN 60898 A 3 x 10 3 x 10 Power cord min cross section mm 5 x 1 5 5 x 1 5 Wire without plug Wire length inch mm 78 3 4 2 000 78 3 4 2 000 Standard voltage B only 2N AC 400 V 2N AC 400 V Frequency Hz 50 50 Total rated load kW 5 5 5 5 Fuse rating B trip rating according to EN 60898 A 2 x 16 2 x 16 Power cord min cross section mm 4 x 2 5 4 x 2 5 Wire without plug Wire length inch mm 78 3 4 2 000 78...

Page 10: ...rating A 2 x 30 Power cord min cross section 3 x AWG10 Wire with plug Wire length inch mm 78 3 4 2000 Cold water KW Permissible water flow pressure PSI kPa 1 45 14 5 100 1 000 1 45 14 5 100 1 000 Required flow rate cold water connection only gal min l min 2 9 11 2 9 11 Required flow rate with additional hot water connection gal min l min 2 6 10 2 6 10 Average water consumption 60 C standard progra...

Page 11: ...spensing DOS Connection for liquid dispensing agents Max no of dispenser pumps No 6 6 XCI box LG interface Installation on machine feet F No of machine feet No 4 4 Machine foot height adjustable with thread inch mm 5 16 8 5 16 8 Machine foot diameter inch mm 10 5 40 10 5 40 Anchoring B Standard floor anchoring Floor anchor kit for 2 machine feet with anchors Wood screws according to DIN 571 inch m...

Page 12: ...16 23 13 16 900 605 Installation dimensions Min side gap inch mm 13 16 20 13 16 20 Recommended side gap washer dryer stack inch mm 11 13 16 300 11 13 16 300 Min distance to opposite wall from front of machine inch mm 37 3 8 950 37 3 8 950 Recommended distance to opposite wall from front of machine inch mm 43 5 16 1 100 43 5 16 1 100 Weights and floor loads Machine weight net weight lb kg 227 103 2...

Page 13: ...nts of the electric utility company If converting the machine to an alternative voltage follow the instructions in the wiring diagram Conversion must be performed by Miele Technical Service or by an authorized service technician The heater rating must also be adapted The machine must not be connected to devices such as timers which would switch it off automatically References to cable cross sectio...

Page 14: ...ges may only be carried out by your Miele dealer or Miele Technical Service Interface The machine can be retrofitted with an XKM 3200 WL PLT communication module This module can be used as a WiFi or LAN interface The LAN interface provided via the module complies with SELV Safety Extra Low Voltage in accordance with EN 60950 Connected appliances must also comply with SELV The LAN connection uses a...

Reviews: