background image

PWM 908 

en-US 

 

11 282 580/00 

Installation 

 
 
 
 
 
 
 
 

305

145,5

145,5

68

1

1

0

3

1

B

B

B

B

BS

B

B

305

145,5

145,5

305

1

0

3

1

B

B

148

148

305

148

148

BS

 

 

 

Summary of Contents for PWM 908 DP

Page 1: ...hing Machine PWM 908 DV DP Always read the operating and installation instructions before setting up installing and commissioning the machine This prevents both personal injury and damage to the machine en US 11 282 580 00 ...

Page 2: ...20 1348 proservice mieleusa com Legend Connection required Connection optional or required depending on model DV Drain valve KW Cold water connection AW Drain connection DP Drain pump B Machine anchoring PA Equipotential bonding and grounding DOS Dispenser connection SLA Peak load connection EL Electrical connection UG Closed plinth F Machine feet adjustable UO Open plinth KG Payment system APCL W...

Page 3: ...PWM 908 en US 11 282 580 00 3 Machine dimensions F F F F F F F F EL KGA SLA XKM DP DV KW WW DOS PA ...

Page 4: ...PWM 908 en US 4 11 282 580 00 Installation EL WW KW KG DV DP KG WW KW EL DP DV KGA SLA EL WW KW KG DP UO UG DV UO UG KG WW KW EL DP DV KGA SLA PA PA ...

Page 5: ...PWM 908 en US 11 282 580 00 5 Washer dryer stack F F EL WW KW DP DV EL WW KW F F APCL APCL KGA SLA DV PA ...

Page 6: ...PWM 908 en US 6 11 282 580 00 Installation 305 145 5 145 5 681 1031 B B B B BS B B 305 145 5 145 5 305 1031 B B 148 148 305 148 148 BS ...

Page 7: ...PWM 908 en US 11 282 580 00 7 Installation UO UG B B UO UG B B UO UG B B B B UO UG B B B B ...

Page 8: ...min cross section mm 3 x 1 5 3 x 1 5 Non standard voltages MAR 400 440 480 Marine 3 AC 400 440 480V Frequency Hz 50 60 Total rated load kW 3 6 4 23 5 0 Fuse rating B trip rating according to EN 60898 A 3 x 16 Power cord min cross section mm 4 x 1 5 Wire without plug Wire length inch mm 78 3 4 2 000 Non standard voltage MAR 230 Marine 3 AC 230 V Frequency Hz 50 60 Total rated load kW 4 4 Fuse ratin...

Page 9: ...to EN 60898 A 3 x 10 3 x 10 Power cord min cross section mm 5 x 1 5 5 x 1 5 Wire without plug Wire length inch mm 78 3 4 2 000 78 3 4 2 000 Standard voltage B only 2N AC 400 V 2N AC 400 V Frequency Hz 50 50 Total rated load kW 5 5 5 5 Fuse rating B trip rating according to EN 60898 A 2 x 16 2 x 16 Power cord min cross section mm 4 x 2 5 4 x 2 5 Wire without plug Wire length inch mm 78 3 4 2 000 78...

Page 10: ...rating A 2 x 30 Power cord min cross section 3 x AWG10 Wire with plug Wire length inch mm 78 3 4 2000 Cold water KW Permissible water flow pressure PSI kPa 1 45 14 5 100 1 000 1 45 14 5 100 1 000 Required flow rate cold water connection only gal min l min 2 9 11 2 9 11 Required flow rate with additional hot water connection gal min l min 2 6 10 2 6 10 Average water consumption 60 C standard progra...

Page 11: ...spensing DOS Connection for liquid dispensing agents Max no of dispenser pumps No 6 6 XCI box LG interface Installation on machine feet F No of machine feet No 4 4 Machine foot height adjustable with thread inch mm 5 16 8 5 16 8 Machine foot diameter inch mm 10 5 40 10 5 40 Anchoring B Standard floor anchoring Floor anchor kit for 2 machine feet with anchors Wood screws according to DIN 571 inch m...

Page 12: ...16 23 13 16 900 605 Installation dimensions Min side gap inch mm 13 16 20 13 16 20 Recommended side gap washer dryer stack inch mm 11 13 16 300 11 13 16 300 Min distance to opposite wall from front of machine inch mm 37 3 8 950 37 3 8 950 Recommended distance to opposite wall from front of machine inch mm 43 5 16 1 100 43 5 16 1 100 Weights and floor loads Machine weight net weight lb kg 227 103 2...

Page 13: ...nts of the electric utility company If converting the machine to an alternative voltage follow the instructions in the wiring diagram Conversion must be performed by Miele Technical Service or by an authorized service technician The heater rating must also be adapted The machine must not be connected to devices such as timers which would switch it off automatically References to cable cross sectio...

Page 14: ...ges may only be carried out by your Miele dealer or Miele Technical Service Interface The machine can be retrofitted with an XKM 3200 WL PLT communication module This module can be used as a WiFi or LAN interface The LAN interface provided via the module complies with SELV Safety Extra Low Voltage in accordance with EN 60950 Connected appliances must also comply with SELV The LAN connection uses a...