Technisches Datenblatt / Technical datasheet: PW 6207 EL 
Datum / Date: 12-01-2011

  

Seite / Page:  

8

 

 

 

 

The electrical connection may only be made to an electrical 
system listed in accordance with the national laws, ordin-
ances and directives as well as the local provisions. In 
addition to this, the regulations of the power supply utility, 
the accident prevention regulations and the insurance com-
pany applicable at the site of installation as well as the 
recognized standards of technology must also be observed. 

The installation must be performed by a qualified person 
(electrician). 

The appliance can be connected either via permanent 
connections or via plug connections according to IEC 
60309-1. Wall receptacles or mains separation devices 
must be accessible after the appliance is installed. 

However, we recommend connecting the appliance via a 
plug connection so that an electrical safety check can be 
carried out, e.g. during repair or maintenance. 

If it is necessary to install a residual current device (RCD) in 
accordance with the local regulations, a residual current 
device type B (AC/DC-sensitive) must always be used. 

 

 

 

Potential 

equalization 

Externally threaded supports  

3/8” x 1 3/8” 

10 × 35 mm 

for shims and nuts  

10 M 

10 M 

Accessories such as shims and nuts are only included with 
the OS version. 

 

 

If necessary, equipotential bonding with good galvanic 
contact must be created, in compliance with all applicable 
local installation specifications. 

 

 

 

Peak load switch-

off 

Connected voltage for the control contacts 

AC 230 V 

AC 230 V 

Connection cable, min. cross-section 

5 × 1.5 mm²

 

5 × 1,5 mm² 

Connection cable not included. 

 

 

 

 

We recommend making the connection with a flexible con-
nection line and an additional separator. When installed, the 
separator should be visible and directly accessible. 

 

 

 

Cold water 

Soft water 

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

Water pressure/Max. flow rate 

145.04 psi 

1.000 kPa 

Max. volume flow 

5.7 gal/min 

26 l/min 

 

 

Max. volume flow (in absence of hot and hard water supply)  9.2 gal/min 

42 l/min 

 

 

2 Connector hoses with threaded joint ¾“ including Y fitting 
(¾“ / 1“) included with the unit. 

 

 

 

 

Threaded connector fitting at site as per DIN 44 991 (flat 
sealing) 

1“ external 
thread 

1“ external 
thread 

 

 

Length of connector hose 

4‟ 11 1/16” 

1,500 mm 

 

 

Average water requirement for a standard program (60° 
colored washing) determined at cold, hot and hard water 
connection. 

30.6 gal/h  

approx. 116 l/h 

 

 

If no hot water, add the corresponding water requirement to 
the cold water requirement. 

 

 

 

 

If connecting to industrial water (option), subtract that water 
requirement from the cold water requirement. 

 

 

 

Hot water Soft 

water 

Max. water temperature 

158°F 

70 °C 

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

Water pressure/Max. flow rate 

145.04 psi 

1.000 kPa 

 

 

Max. volume flow  

4.2 gal/min 

16 l/min 

 

 

1 Connector hose with threaded joint ¾“ included with the 
unit. 

 

 

 

 

Threaded connector fitting at site as per DIN 44 991 (flat 
sealing) 

¾" external 
thread 

¾" external 
thread 

 

 

Length of connector hose 

4‟ 11 1/16” 

1,500 mm 

 

 

Average water requirement for a standard program (60° 
colored washing) determined at cold, hot and hard water 
connection. 

31.4 gal/h  

approx. 119 l/h 

 

 

If no hot water supply, connect hose to cold water! 

 

 

 

 

Summary of Contents for PW 6107 EL

Page 1: ...11 11 M Nr 09 284 490 01 Installation plan Washer PW 6207 EL en US ...

Page 2: ...M Nr 09 284 490 01 2 ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ... mm Minimum height 3 15 16 100 mm Min platform width 36 1 4 920 mm Min platform depth 41 5 16 1 050 mm WI Weighing system Version with built in weighing system OS Offshore Special version Offshore Machine connections 1 Standard voltage as delivered 3 AC 220 240 V 3 AC 220 240 V Frequency 50 60 Hz 50 60 Hz Rated load 18 kW 18 kW Fuse rating 3 x 50 A 3 x 50 A Connection cable min cross section 4 x 1...

Page 8: ... the control contacts AC 230 V AC 230 V Connection cable min cross section 5 1 5 mm 5 1 5 mm Connection cable not included We recommend making the connection with a flexible con nection line and an additional separator When installed the separator should be visible and directly accessible Cold water Soft water Water pressure Min flow rate 14 5 psi 100 kPa Water pressure Max flow rate 145 04 psi 1 ...

Page 9: ...200 l min Vented drainage required If ventilation is insufficient fit Miele kit Mat no 05238090 Drain manifolds serving several machines must be of suffi cient cross section Fittings without plinth It is essential to ensure that the appliance is fastened ade quately to the substrate Fastening material included with unit 2 wood screws DIN 571 Ø length 1 2 x 3 9 16 12 x 90 mm 2 screw anchors Ø lengt...

Page 10: ...ments and conditions The appliance is supplied without feet so that the female thread can be used for fastening with studs Machine data Width 36 3 8 924 mm Depth 44 1 2 1 130 mm Height 55 1 8 1 400 mm Housing width 36 1 4 920 mm Housing depth 40 3 16 1 020 mm Width loading opening clear width 36 5 8 930 mm Recommended wall spacing to front edge of appliance front 57 1 16 1 450 mm Minimum wall spac...