Cold water 

Hard water 

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

Water pressure/Max. flow rate 

145.04 psi 

1,000 kPa 

Max. volume flow 

7 gal/min 

32 l/min 

 

 

2 Connector hoses with threaded joint ¾“ including Y fitting 
(¾“ / 1“) optionally included with the unit. 

 

 

 

 

Threaded connector fitting at site as per DIN 44 991 (flat 
sealing) 

1“ external 
thread 

1“ external 
thread 

 

 

Length of connector hose 

4„ 11 1/16“ 

1,500 mm 

 

 

Average water requirement for a standard program (60° 
colored washing) determined at cold, hot and hard water 
connection. 

19 gal/h  

approx. 72 l/h 

 

Cold water 

Liquid dispensing 

Water pressure/Min. flow rate 

14.5 psi 

100 kPa 

Water pressure/Max. flow rate 

145.04 psi 

1,000 kPa 

Max. volume flow 

1.45 gal/min 

5.5 l/min 

 

 

1 Connector hose with threaded joint ¾“ optionally included 
with the unit. 

 

 

 

 

Threaded connector fitting at site as per DIN 44 991 (flat 
sealing) 

¾" external 
thread 

¾" external 
thread 

 

 

Length of connector hose 

4‟ 11 1/16” 

1.500 

 

Drainage 

Dump valve 

 

Max. water outflow temperature 

203°F 

95 °C 

Drainage supports in machine (outer diameter) 

2 15/16“  
[DN 2 3/4“] 

75 mm [DN 70] 

On-site drain connection (inner diameter) 

2 15/16“ [DN  
2 3/4“ sleeve] 

75 mm [DN 70 
sleeve] 

Max. transient throughput 

43.99 gal/min 

200 l/min 

 

 

Vented drainage required. If ventilation is insufficient, fit 
Miele kit, Mat. no. 05238090. 
Drain manifolds serving several machines must be of suffi-
cient cross-section. 

 

 

 

Fittings 

without plinth  

 

 

It is essential to ensure that the appliance is fastened ade-
quately to the substrate! 

 

 

Fastening material included with unit: 

 

 

 

 

   2 × wood screws DIN 571 (Ø × length) 

1/2” x 3 9/16” 

12 x 90 mm 

 

 

   2 × screw anchors (Ø × length) 

5/8” x 3 1/8” 

16 x 80 mm 

 

 

A sufficiently firm substrate with sufficient load-bearing 
capacity is necessary for the installation. The fastening 
material included is only suitable for a solid concrete sub-
strate. The fastening material for other suitable substrates 
must be provided on site. 

 

 

 

 

on concrete platform 

 

 

It is essential to ensure that the appliance is fastened ade-
quately to the substrate! 

 

 

Fastening material included with unit: 

 

 

 

 

   2 × wood screws DIN 571 (Ø × length) 

1/2” x 3 9/16” 

12 x 90 mm 

 

 

   2 × screw anchors (Ø × length) 

5/8” x 3 1/8” 

16 x 80 mm 

 

 

The quality of the concrete and its strength must be as-
sessed according to the machine load. Ensure that the 
location of the platform is fixed adequately in the case of 
dynamic loads! 

 

 

 

 

Miele base 

 

 

It is essential to ensure that the base is fastened adequately 
to the substrate! 

 

 

Fastening material included with base: 

 

 

 

 

   4 × wood screws DIN 571 (Ø × length) 

5/16“ x 3 1/8“ 

8 x 80 mm 

 

 

   4 × screw anchors (Ø × length) 

1/2“ x 2 3/8“ 

12 x 60 mm 

 

 

The installation and assembly of the appliance and base 
must follow the installation instructions provided 

 

 

 

 

Summary of Contents for PW 6107 EL

Page 1: ...11 11 M Nr 09 284 490 01 Installation plan Washer PW 6207 EL en US ...

Page 2: ...M Nr 09 284 490 01 2 ...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ... mm Minimum height 3 15 16 100 mm Min platform width 36 1 4 920 mm Min platform depth 41 5 16 1 050 mm WI Weighing system Version with built in weighing system OS Offshore Special version Offshore Machine connections 1 Standard voltage as delivered 3 AC 220 240 V 3 AC 220 240 V Frequency 50 60 Hz 50 60 Hz Rated load 18 kW 18 kW Fuse rating 3 x 50 A 3 x 50 A Connection cable min cross section 4 x 1...

Page 8: ... the control contacts AC 230 V AC 230 V Connection cable min cross section 5 1 5 mm 5 1 5 mm Connection cable not included We recommend making the connection with a flexible con nection line and an additional separator When installed the separator should be visible and directly accessible Cold water Soft water Water pressure Min flow rate 14 5 psi 100 kPa Water pressure Max flow rate 145 04 psi 1 ...

Page 9: ...200 l min Vented drainage required If ventilation is insufficient fit Miele kit Mat no 05238090 Drain manifolds serving several machines must be of suffi cient cross section Fittings without plinth It is essential to ensure that the appliance is fastened ade quately to the substrate Fastening material included with unit 2 wood screws DIN 571 Ø length 1 2 x 3 9 16 12 x 90 mm 2 screw anchors Ø lengt...

Page 10: ...ments and conditions The appliance is supplied without feet so that the female thread can be used for fastening with studs Machine data Width 36 3 8 924 mm Depth 44 1 2 1 130 mm Height 55 1 8 1 400 mm Housing width 36 1 4 920 mm Housing depth 40 3 16 1 020 mm Width loading opening clear width 36 5 8 930 mm Recommended wall spacing to front edge of appliance front 57 1 16 1 450 mm Minimum wall spac...

Reviews: