Venting more than one dryer
via the same ducting system
Building regulations approval may
be required. Contact your local
planning authorities for advice.
,
For each dryer there
must
be
one non-return flap
R
installed
directly on the main venting duct. The
items required for this are available
as optional accessories (see right).
,
Otherwise condensation could
trickle back into the dryer causing
damage and endangering its
electrical safety.
When installing 3 to max. 5 dryers,
pipe diameter
D
must be increased.
Number
of dryers
Magnification factor for the pipe
diameter from Table II
3
4 - 5
1.25
1.5
1 Connection to the main venting duct
2 Miele non-return flap*
3 Additional Miele adapter*
4 Miele flexible ducting hose*
^
Push the non-return flap (2) all the
way into the adapter (3).
Installation - extraction ducting
56