Height
250 cm (minimum room height)
Width
115 cm
Depth
87 cm
Weight (net)
Approx. 550 kg
Operating weight
Approx. 800 kg
Voltage
see data plate
Connected load
see data plate
Fuse rating
see data plate
Compressed air connection
600 kPa (6.0 bar) required for steam
operation
Steam connection:
with electric TA
with steam TA
250 - 1000 kPa / 140 - 180 °C
250 - 600 kPa * / 140 - 164 °C
Water pressure (flow rate)
200 - 1000 kPa overpressure
Water connection:
Cold, hot and de-ionised (AD) water
§
up to max. 70 °C
Ambient temperature
5 °C to 40 °C
Relative humidity: maximum
decreasing proportionately to
80 % for temperatures to 31 °C
50 % for temperatures to 40 °C
Altitude
Max. 1500 m
#
Soiling level
(according to IEC/EN 61010-1)
P2
Protection category
(according to IEC 60529)
IP20 (Dust permeation)
Noise level in dB (A), Sound level LpA
in washing and drying
< 70
Test marks
VDE, radio interference suppression
!
mark
MDD-Guidelines 93/42/EWG, Class IIb
Manufacturer's address
Miele & Cie. KG, Carl-Miele-Str. 29,
33332 Gütersloh, Germany
* if the steam pressure lies between 250 - 300 kPa (2.5 – 3.0 bar) the steam drying
unit (TA) will only reach a max. drying temperature of 90 - 100 °C.
§
for AD water connection with special version with DK+WRG max. 20°C
#
If installed at altitudes above 1500 m the boiling point of the suds solution will be
lower. Disinfecting temperature parameters should be lowered and the holding
time increased (A
0
value).