![Miele KM 7404 FX Operating And Installation Instructions Download Page 55](http://html.mh-extra.com/html/miele/km-7404-fx/km-7404-fx_operating-and-installation-instructions_234398055.webp)
Problem solving guide
55
Many malfunctions and faults that can occur in daily operation can be easily
remedied. Time and money will be saved because a service call will not be
needed.
The following guide may help you to find the reason for a malfunction or a fault,
and to correct it.
Issue
Cause and remedy
The hob or cooking
zones cannot be
switched on.
There is no power to the hob.
Check if the mains fuse has tripped. If it has,
contact a qualified electrician or your Miele dealer
(minimum fuse rating - see data plate).
There may be a technical fault.
Disconnect the appliance from the electricity
supply for approx. 1 minute. To do this:
– switch off at the isolator, or
– disconnect the mains fuse.
If, after resetting the trip switch in the mains fuse
box and switching the appliance back on, the
appliance will still not heat up, contact a qualified
electrician or your Miele dealer.
A smell and vapours are
given off when the new
appliance is being used.
The metal components have a protective coating.
When the appliance is used for the first time, this
causes a smell and possibly also vapour. The
material from which the induction coils are made also
gives off a smell in the first few hours of operation.
With each subsequent use, the odour is reduced until
it disappears completely. The smell and any vapours
given off do not indicate a faulty connection or
appliance and they are not hazardous to health.
In the cooking zone
display, the
symbol
will flash alternately
with the selected power
level or
.
An unsuitable pan has been placed on the hob.
Use suitable pans (see “Pans” in the “Induction”
chapter).
After the hob has been
switched on, or after
touching a sensor,
appears in the timer
display for a few
seconds.
The system lock or safety lock is activated.
Deactivate the system lock or safety lock (see
“System lock / Safety lock”).
Summary of Contents for KM 7404 FX