Technical data
62
Height
Height incl. steam condenser (DK)
2000 mm (space required)
2400 mm (space required)
Width
900 mm
Depth
Depth with door open
750 mm
1485 mm
Useable cabinet dimensions H/W/D
683/541/610 mm
Weight (net)
Approx. 505 kg
Operating weight
Approx. 665 kg
Voltage
See data plate
Connected load
See data plate
Fuse rating
See data plate
Compressed air connection
600 kPa (required for steam operation)
Steam connection with
electric drying unit (TA)
steam drying unit (TA)
250 - 1000 / 140 - 180 kPa / °C
250 - 600 / 140 - 164 kPa */ °C
Water pressure (flow rate)
200 - 1000 kPa
Water connection: cold, hot and DI water
Up to max. 70 °C
Ambient temperature
5 °C - 40 °C
Relative humidity
maximum
linear decreasing to
80% for temperatures up to 31°C
50 % for temperatures up to 40 °C
Altitude above sea level
up to 1500 m
#
Soiling level (according to IEC/EN 61010-1)
P2
Overvoltage category (according to IEC
60664)
II
Protection category (according to IEC
60529)
IP20 (dust penetration)
Noise level in dB (A), sound pressure LpA
during cleaning and drying phases
< 70
Test certificates awarded
VDE, radio and television suppressed
mark
MDD guidelines 93/42/EEC, Class IIb
Manufacturer's address
Miele & Cie. KG, Carl-Miele-Straße
29,33332 Gütersloh, Germany
* * If the steam pressure lies between 250 - 300 kPa, (2.5 - 3 bar) the steam drying unit (TA)
will only reach a maximum drying temperature of 90 - 100°C.
# If installed at altitudes above 1500 m the boiling point of the suds solution will be lower.
Disinfecting temperature parameters should be lowered and the holding time increased (A0
value). This must be done by a Miele authorised service technician.