Operation
46
Programme sequence
The programme will start automatically automatically as soon as the
Start button is pressed.
The programme stages are shown in the display during the pro-
gramme sequence.
Detailed information on programme sequence is given in the ap-
pendix of the Programming manual.
On machines with a built-in printer you must not change the
colour ribbon cartridge or the paper roll whilst a programme is in
progress.
At the end of the programme
At the end of the programme PROGRAMME - END is shown in the
display and the background lighting flashes.
Press any button to stop the lighting from flashing.
See "System functions" in the Programming manual for further in-
formation on switching off the flashing lighting.
Cancelling a programme
A programme can only be interrupted or cancelled in operating
levels B and D.
When testing to EN ISO 15883-1 or Cf PP 01-01, the programme
must not be interrupted or cancelled.
In operating levels
B or D
Press the Stop button
.
The programme is interrupted.
The following will appear in the display:
CANCEL OR>CONTINUE<
With established decontamination programmes any contamin-
ated water must be decontaminated using a disinfecting agent be-
fore it is discharged into the sewerage system. The door on the un-
clean side of the machine can be opened to do this.
Use cursor
to select >CANCEL<, the > < cursors will start flash-
ing.
Press the Start button
.
The programme is cancelled and the water pumped away.
WATER DRAIN appears in the display.