CVA615 Coffee System
6.3 Displayed Messages
Displayed Message
Information
BREW UNIT BLOCKED
The brew unit is dirty.
The brew unit is blocked.
The brew unit is Jammed.
•
Clean / inspect brew unit / check drives
EXPEL AIR
Air is present with the water system –
•
Perform “Expel Air” procedure.
FILL COFFEE BEANS
The bean container is empty OR
The grinder may be jammed.
•
Add coffee beans to the beans
container.
•
Clean the conical grinder (top of grinder)
BREW UNIT MISSING
Brew unit is not installed OR
Not installed correctly.
•
Reinstall the brew unit
•
Check brew unit present switch
DESCALING
•
Perform the Descale Procedure.
WASTE UNIT MISSING
Waste unit is not installed
•
Re-install the waste unit
•
Check magnet on rear of waste unit
•
Check brew unit present switch
Table 6-3:
Displayed Messages (continued on Table 6-4)