Before installing the appliance check
that the location provides the required
clearances from combustible material
and if necessary provide protection to
adjacent surfaces as required by
regulations.
The minimum
side clearance
to a
combustible surface* shall be a
300 mm horizontal distance from the
periphery of any electric element.
The minimum
rear clearance
from an
appliance to a
–
combustible surface*
shall be a
200 mm horizontal distance from the
periphery of any electric element.
–
non-combustible surface
or
splashback shall be a 50 mm
horizontal distance from the rear
edge of the appliance.
If the clearance between the periphery
of the electric element and
- the side wall is less than 300 mm
- the rear wall is less than 200 mm, the
walls must be protected with a
non-combustible material.
The protection must be extended a
minimum distance of 150 mm above
the electric element. The shown area
indicates the protected surface, which
may be ceramic tiles or other approved
material.
Example:
* Combustible surface:
The surface of a material that is
capable of catching fire and burning
at temperatures exceeding 50 K
above ambient.