Converting to another gas type
54
Conversion from one type of gas
to another, should only be under-
taken by an approved and registered
gas installer in strict accordance with
current local and national safety and
building regulations.
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Main jet
Simmer ad-
justment jet
Natural gas H
1.75
Nr. 34
0.88/0.42
Liquid gas
1.12
Nr. 7
0.60/0.23
Changing the jets
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
When converting to another type of
gas, both the main
and
small jets
need to be changed.
The upper part of the appliance has to
be removed before the jets can be
changed.
Remove the burner caps
, burner
ring
and burner head
.
Undo the screws
.
Pull the control knob off.