Converting to another gas type
58
Functional check
Check all gas fittings for leaks.
Reassemble the hob.
Ignite all burners to check that they
are operating correctly.
– The flame must not go out on the
lowest setting, or when the control is
turned quickly from the highest to the
lowest setting.
– On the highest setting, the flame
must have a distinctive and visible
core.
Adhere the label supplied with the
jets, stating the type of gas being
used.