Technical Information
81
CVA 4062/CVA 4066/CVA 4068 Coffee Systems
3.5
F10 -- No Water Intake
Cause:
Water container inserted incorrectly.
Remedy:
Insert the water container correctly.
Cause:
Hose connections interrupted, blocked or kinked.
Remedy:
1. Check hose connections.
2. Replace hoses, if necessary.
Cause:
Water container valve jammed or clogged.
Remedy:
1. Check water container valve.
2. Replace water container, if necessary.
Cause:
Flow meter (B3/4) defective or clogged.
Remedy:
1. See
Flow Meter (B3/4) Removal
, Section 051-4.5.
2. Install a new flow meter.
Cause:
Coffee/hot water pump (2M7) defective.
Remedy:
1. See
Coffee/Hot Water Pump Removal
, Section 051-4.3.
2. Install a new coffee/hot water pump.
Cause:
Water paths need to be descaled.
Remedy:
1. Descale the appliance; see the operating instructions.
2. Replace the coffee/hot-water heater, including the brew-unit hose and spout.
Cause:
Brew unit jammed.
Remedy:
Follow the remedy procedure outlined in
F73 -- Brew Unit Fault
(Page 83).
Warning!
In order to avoid possible water system faults (e.g., clogging or blocking of valves),
grease, oil or other slip lubricants should never be used when assembling and
installing water system parts.
3.6
F17 -- Insufficient Water Intake
Cause:
Water container inserted incorrectly.
Remedy:
Insert the water container correctly.
Summary of Contents for COFFEE SYSTEM CVA 4068
Page 1: ...TECHNICAL INFORMATION CVA 406x Coffee Systems 2012 Miele USA ...
Page 18: ...Technical Information 18 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 010 Housing ...
Page 23: ...Technical Information 23 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 011 Exterior Side Panels ...
Page 24: ...Technical Information 24 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 020 Door Inner Panel ...
Page 35: ...Technical Information 35 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 030 Drive Brew Unit ...
Page 45: ...Technical Information 45 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 040 Grinder ...
Page 50: ...Technical Information 50 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 050 Flow Thru Heaters ...
Page 78: ...Technical Information 78 CVA 4062 CVA 4066 CVA 4068 Coffee Systems 070 Electronic Modules ...
Page 118: ...Technical Information 118 CVA 4062 CVA 4066 CVA 4068 Coffee Systems ...