background image

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

4

 

EXP-1003 HD

Chapter 8: Utility 

26

Clock 26

Mode 26
Time 26
Format 26
Date 26

Users 26

Entering A New User ID 

26

Deleting A User ID 

27

Editing A User 

27

Shop 27
Display 27

Contrast Level 

27

Backlight Time 

28

Coupon 28
Edit Coupon 

28

Temp 28
Language 28
Format 28
Update 28

Chapter 9: Maintenance & Troubleshooting 

29

TTesting Clamp Continuity 

29

Performing A Continuity Test 

29

Internal Batteries 

29

Battery Power Indicator 

29

Replacing The Tester Batteries 

29

Troubleshooting 30

The Display Does Not Turn On 

30

The STATUS LED Flashes 

30

Data Will Not Print 

30

Appendix: Templates 

31

Header And Coupon Templates 

31

Summary of Contents for EXP-1003 HD

Page 1: ...ION MANUAL September 2013 167 000505EN A EXP 1003 HD Expandable Electrical Diagnostic Platform For testing 6 and 12 volt heavy duty automotive and commercial batteries and 12 volt and 24 volt charging...

Page 2: ...Blank page...

Page 3: ...Power up 11 Chapter 2 Battery Test 12 Additional Test Requirements 12 System Noise Detected 12 Unstable Battery Detected 13 Deep Scan Test 13 Battery Test Results 13 Battery Test Results 13 Chapter 3...

Page 4: ...27 Contrast Level 27 Backlight Time 28 Coupon 28 Edit Coupon 28 Temp 28 Language 28 Format 28 Update 28 Chapter 9 Maintenance Troubleshooting 29 TTesting Clamp Continuity 29 Performing A Continuity T...

Page 5: ...instructions and BCI Battery Council International safety recommendations which include the following precautions Battery acid is highly corrosive If acid enters your eyes immediately flush them thoro...

Page 6: ...he cable connector Data Card The analyzer ships with a plastic insert in the data card slot to protect it from dust and debris To remove the plastic insert or a data card push briefly on its edge to r...

Page 7: ...y when you connect its test leads to a battery Title Bar The title bar shows you the name of the current menu test tool utility or function Selection Area The selection area below the Title Bar contai...

Page 8: ...Scrolling lists contain items that extend above and below the screen The first number above the right soft key indicates the position in the list of the highlighted item The second number above the r...

Page 9: ...ct in the Utilities Menu Tests a circuit for continuity and resistance measured in ohms Tests a diode for forward voltage drop Measures two signals simultaneously DC voltage and amperage Info Menu The...

Page 10: ...you see any of these defects replace the battery Corroded loose or damaged cables and connections Re pair or replace them as needed Corrosion on the battery terminals and dirt or acid on the case top...

Page 11: ...h to tighten the adapters more than turn Testing the Battery Pack 1 At the start of the test make sure all vehicle accessory loads are off the key is not in the ignition and the doors are closed 2 Con...

Page 12: ...Amps specified by SAE The amount of current a battery can provide at 0 F 17 8 C 100 to 3000 CA Cranking Amps The amount of current a battery can provide at 32 F 0 C 100 to 3000 Rating Description Ran...

Page 13: ...view the code press or The tester will generate a test code for all REPLACE decisions To send the results to the IR printer align the analyzer s IR transmitter with the printer s receiver and press P...

Page 14: ...to select the battery RATING UNITS printed on the battery label and press NEXT to continue or press the corresponding number key If the information is un readable contact the battery manufacturer 1 C...

Page 15: ...ied by SAE The amount of current a battery can provide at 0 F 17 8 C 100 to 3000 CA Cranking Amps The amount of current a battery can provide at 32 F 0 C 100 to 3000 MCA Marine Cranking Amps The amoun...

Page 16: ...Of Health Battery State Of Charge Estimated charge time if needed Auto Van Test Decisions Decision Recommended Action GOOD BATTERY Return the battery to service GOOD RECHARGE Fully charge the battery...

Page 17: ...rvice CHARGE RETEST Fully charge the battery and retest Failure to fully charge the battery before retesting may cause false readings If CHARGE RETEST appears again replace the battery REPLACE BATTERY...

Page 18: ...y charged check the clamp connections Starter System Test 1 Following a successful Battery Test press NEXT to contin ue to the Starter System Test NOTE When testing a battery pack connect the test cab...

Page 19: ...lter nator or there is stator damage 7 TURN HIGH BEAMS AND BLOWER MOTOR ON IDLE EN GINE After a few seconds the tester will ask you to turn on the accessory loads It will determine if the charging sys...

Page 20: ...have a built in regulator requiring you to replace the alternator In older vehicles that use external voltage regulators you may need to replace only the voltage regulator The regulator controls volta...

Page 21: ...xt test is performed To print the results align the analyzer s IR transmitter with the printer s receiver and select PRINT To return to the Main Menu press END 1 In the Main Menu select the Print View...

Page 22: ...d connections as shown in the illustration below 1 Connect the battery test leads at the component s output lead the B or output screw on the alternator and the component s housing as ground 2 Connect...

Page 23: ...n volts The scope allows you to print the voltage trace to the optional IR printer when you freeze the signal Align the analyzer s IR transmitter with the printer s receiver and select PRINT To return...

Page 24: ...e Resolution Accuracy Overload Protection 0 70 A 0 01 A 3 of reading 1A 1000 Arms 0 700 A 0 1 A 3 of reading 1A 1000 Arms Accuracies are specified from 2 to 100 of range Aac Range Resolution Accuracy...

Page 25: ...used User Totals USER TOTALS displays the total tests performed by User ID four IDs per screen Totals by Decision The first screen displays the number of battery tests by decision The second screen d...

Page 26: ...option button no additional keypress is needed to save or continue to the next step Clock The CLOCK ADJUST utility has four settings Use the ARROW keys to highlight the setting you want to change MOD...

Page 27: ...1 GREG 2 WAYNE 3 GREG 4 USER04 3 Press NEXT to edit the selected user Shop The SHOP INFO utility allows you to create a header for your printed test results showing your business location information...

Page 28: ...it Coupon The EDIT COUPON utility allows you to create a pro motional coupon or message for your customers that prints at the bottom of every test result Its two infor mation screens contain eight lin...

Page 29: ...ppropriate clamp Black Clamp Bottom Jaw Black Clamp Top Jaw Red Clamp Bottom Jaw Red Clamp Top Jaw Cable Connector Pin outs NOTE Use a small wire or a paper clip if your ohmme ter probe tip is too lar...

Page 30: ...of the analyzer and on the printer below the MODE button should be pointed directly at each other The maximum distance for reliable transmission between the ports is 17 in 45 cm To realign press the E...

Page 31: ...lp you edit and center your coupon use the template below to lay out your coupon information below before entering it into the Battery Diagnostic Station Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line...

Page 32: ...ing the unit or damage resulting from extraneous causes including owner misuse Midtronics is not liable for any incidental or consequential damages for breach of this warranty The warranty is void if...

Reviews: