Chapter 3: System Test

EXP-1003 HD

  The System Test evaluates the battery, starting and 

charging systems.  The System Test includes Battery 

Test to eliminate it as the cause of starting or charging 

problems.

The BACK key returns you to the Main Menu at the start of the 

test and to the previous screen as you progress.

Auto/Van

1.  Use the ARROW keys to highlight the System Test icon 

and press NEXT to continue.

2.  Use 

 or 

 to select AUTO/VAN at the VEHICLE TYPE 

screen  and press NEXT to continue, or press the corre-

sponding number key.

 AUTO/VAN

 TRUCK

3.  Use 

 or 

 to select the AMP CLAMP availability and press 

NEXT to continue, or press the corresponding number key.
If you select the Amp Clamp, follow the on-screen 

instructions for zeroing out clamp and placing it around 

the negative battery cable before proceeding.

4.  Use 

 or 

 to select the POST TYPE and press NEXT to 

continue, or press the corresponding number key.

 TOP

 SIDE

  JUMP START POST (Car/Van Only)

5.  Use 

 or 

 to select the BATTERY CHEMISTRY and press 

NEXT to continue, or press the corresponding number key.

 FLOODED

 AGM-SPIRAL

 AGM

 GEL

6.  Use 

 or 

 to select the battery RATING UNITS (printed 

on the battery label) and press NEXT to continue, or press 

the corresponding number key.  If the information is un-

readable, contact the battery manufacturer.

 CCA

 CA

 MCA

 JIS

 DIN

 SAE

 IEC

 EN

Rating

Description

Range

CCA

Cold Cranking Amps (specified 

by SAE): The amount of current a 

battery can provide at 0 ºF (–17.8 ºC).

100 to 

3000

CA

Cranking Amps: The amount of 

current a battery can provide at 

32°F (0 ºC).

100 to 

3000

MCA

Marine Cranking Amps: The 

amount of current a battery can 

provide at 32°F (0 ºC).

100 to 

3000

JIS

Japanese Industrial Standard: 

(shown on a battery as a 

combination of numbers and letters.

26A17 to 

245H52

(72 numbers)

DIN

Deutsche Industrie-Norm

100 to 1000

SAE

European labeling of CCA

100 to 3000

IEC

International Electrotechnical 

Commission

100 to 1000

EN

Europa-Norm

100 to 1700

7.  Press 

 or 

 to select the BATTERY RATING or use the nu-

meric keys and press NEXT to continue.

a)  If CCA, scroll to the rating and press SELECT.  The 

entry range is 100 to 3000, except for DIN and IEC, 

which have a range of 100 to 1000.

500

CCA

b)  If JIS, scroll to the JIS number.

26A17

26A19
26B17
28A19

8.  If prompted, measure the ambient battery temperature 

by aim the IR temperature sensor on the top of the tester 

at the battery case.  Once the temperature stabilizes, press 

NEXT to begin the test.

Battery Case 

(Top)

Sensor

Chapter 3: System Test

Summary of Contents for EXP-1003 HD

Page 1: ...ION MANUAL September 2013 167 000505EN A EXP 1003 HD Expandable Electrical Diagnostic Platform For testing 6 and 12 volt heavy duty automotive and commercial batteries and 12 volt and 24 volt charging...

Page 2: ...Blank page...

Page 3: ...Power up 11 Chapter 2 Battery Test 12 Additional Test Requirements 12 System Noise Detected 12 Unstable Battery Detected 13 Deep Scan Test 13 Battery Test Results 13 Battery Test Results 13 Chapter 3...

Page 4: ...27 Contrast Level 27 Backlight Time 28 Coupon 28 Edit Coupon 28 Temp 28 Language 28 Format 28 Update 28 Chapter 9 Maintenance Troubleshooting 29 TTesting Clamp Continuity 29 Performing A Continuity T...

Page 5: ...instructions and BCI Battery Council International safety recommendations which include the following precautions Battery acid is highly corrosive If acid enters your eyes immediately flush them thoro...

Page 6: ...he cable connector Data Card The analyzer ships with a plastic insert in the data card slot to protect it from dust and debris To remove the plastic insert or a data card push briefly on its edge to r...

Page 7: ...y when you connect its test leads to a battery Title Bar The title bar shows you the name of the current menu test tool utility or function Selection Area The selection area below the Title Bar contai...

Page 8: ...Scrolling lists contain items that extend above and below the screen The first number above the right soft key indicates the position in the list of the highlighted item The second number above the r...

Page 9: ...ct in the Utilities Menu Tests a circuit for continuity and resistance measured in ohms Tests a diode for forward voltage drop Measures two signals simultaneously DC voltage and amperage Info Menu The...

Page 10: ...you see any of these defects replace the battery Corroded loose or damaged cables and connections Re pair or replace them as needed Corrosion on the battery terminals and dirt or acid on the case top...

Page 11: ...h to tighten the adapters more than turn Testing the Battery Pack 1 At the start of the test make sure all vehicle accessory loads are off the key is not in the ignition and the doors are closed 2 Con...

Page 12: ...Amps specified by SAE The amount of current a battery can provide at 0 F 17 8 C 100 to 3000 CA Cranking Amps The amount of current a battery can provide at 32 F 0 C 100 to 3000 Rating Description Ran...

Page 13: ...view the code press or The tester will generate a test code for all REPLACE decisions To send the results to the IR printer align the analyzer s IR transmitter with the printer s receiver and press P...

Page 14: ...to select the battery RATING UNITS printed on the battery label and press NEXT to continue or press the corresponding number key If the information is un readable contact the battery manufacturer 1 C...

Page 15: ...ied by SAE The amount of current a battery can provide at 0 F 17 8 C 100 to 3000 CA Cranking Amps The amount of current a battery can provide at 32 F 0 C 100 to 3000 MCA Marine Cranking Amps The amoun...

Page 16: ...Of Health Battery State Of Charge Estimated charge time if needed Auto Van Test Decisions Decision Recommended Action GOOD BATTERY Return the battery to service GOOD RECHARGE Fully charge the battery...

Page 17: ...rvice CHARGE RETEST Fully charge the battery and retest Failure to fully charge the battery before retesting may cause false readings If CHARGE RETEST appears again replace the battery REPLACE BATTERY...

Page 18: ...y charged check the clamp connections Starter System Test 1 Following a successful Battery Test press NEXT to contin ue to the Starter System Test NOTE When testing a battery pack connect the test cab...

Page 19: ...lter nator or there is stator damage 7 TURN HIGH BEAMS AND BLOWER MOTOR ON IDLE EN GINE After a few seconds the tester will ask you to turn on the accessory loads It will determine if the charging sys...

Page 20: ...have a built in regulator requiring you to replace the alternator In older vehicles that use external voltage regulators you may need to replace only the voltage regulator The regulator controls volta...

Page 21: ...xt test is performed To print the results align the analyzer s IR transmitter with the printer s receiver and select PRINT To return to the Main Menu press END 1 In the Main Menu select the Print View...

Page 22: ...d connections as shown in the illustration below 1 Connect the battery test leads at the component s output lead the B or output screw on the alternator and the component s housing as ground 2 Connect...

Page 23: ...n volts The scope allows you to print the voltage trace to the optional IR printer when you freeze the signal Align the analyzer s IR transmitter with the printer s receiver and select PRINT To return...

Page 24: ...e Resolution Accuracy Overload Protection 0 70 A 0 01 A 3 of reading 1A 1000 Arms 0 700 A 0 1 A 3 of reading 1A 1000 Arms Accuracies are specified from 2 to 100 of range Aac Range Resolution Accuracy...

Page 25: ...used User Totals USER TOTALS displays the total tests performed by User ID four IDs per screen Totals by Decision The first screen displays the number of battery tests by decision The second screen d...

Page 26: ...option button no additional keypress is needed to save or continue to the next step Clock The CLOCK ADJUST utility has four settings Use the ARROW keys to highlight the setting you want to change MOD...

Page 27: ...1 GREG 2 WAYNE 3 GREG 4 USER04 3 Press NEXT to edit the selected user Shop The SHOP INFO utility allows you to create a header for your printed test results showing your business location information...

Page 28: ...it Coupon The EDIT COUPON utility allows you to create a pro motional coupon or message for your customers that prints at the bottom of every test result Its two infor mation screens contain eight lin...

Page 29: ...ppropriate clamp Black Clamp Bottom Jaw Black Clamp Top Jaw Red Clamp Bottom Jaw Red Clamp Top Jaw Cable Connector Pin outs NOTE Use a small wire or a paper clip if your ohmme ter probe tip is too lar...

Page 30: ...of the analyzer and on the printer below the MODE button should be pointed directly at each other The maximum distance for reliable transmission between the ports is 17 in 45 cm To realign press the E...

Page 31: ...lp you edit and center your coupon use the template below to lay out your coupon information below before entering it into the Battery Diagnostic Station Line 1 Line 2 Line 3 Line 4 Line 5 Line 6 Line...

Page 32: ...ing the unit or damage resulting from extraneous causes including owner misuse Midtronics is not liable for any incidental or consequential damages for breach of this warranty The warranty is void if...

Reviews: