Chapter 4: CQ Sync

  The  CQ  SNYC  function  enables  you  to  upload  data 

from  the  tester's  internal  memory  to  a  removable 

USB-type flash drive.  You can also use this function 

in reverse to download data into the tester's internal 

memory.

This function can also be used to delete a specific hierarchy 

or the entire contents of the tester's internal memory.  Tester 

software updates are also performed using CQ SYNC. Refer to 

the Max Interface Manual for additional user information.

Upload

  The UPLOAD function lets you upload data from the 

internal memory of the tester to an removable USB-

type flash drive.

1.  From the Main Menu use the ARROW keys to highlight 

the CQ SYNC icon and press the SELECT ITEM soft key.

2.  Highlight the UPLOAD icon and press the SELECT ITEM 

soft key.  A TYPE screen with MEASURE and CAPACITY op-

tions appears on the lower screen.

Measure

 

The MEASURE function lets you export measurement 

data from the internal flash memory in the tester and 

load it onto a USB-type jump drive.

  NOTE:  Measurement  data  can  only  be 

viewed  using  the  Midtronics  Celltraq®  En-

terprise Battery Asset Management System 

software.  Contact your Midtronics sales rep-

resentative for more information.

1.  Use the ARROW keys to highlight the MEASURE icon and 

press the SELECT ITEM soft key.
A FLASH UPLOAD hierarchy of the sites available for data 

upload appears on the top screen and bottom screens of 

the tester.

2.  Use the ARROW keys to highlight the Site, Plant, or String 

you want to upload and press the UPLOAD soft key.

3.  Insert the USB-type flash drive into the proper connecter 

located under the protective cover on the bottom of the 

tester.

4.  Press the UPLOAD soft key to begin the data uploading 

process.  The lower screen will display the CQ SYNC menu 

when the data upload has been completed.

Capacity

  The  CAPACITY  function  lets  you  export  data  tak-

en from the capacity test manager and view it in a 

spreadsheet application such as Microsoft® Excel.

1.  Use the ARROW keys to highlight the CAPACITY icon and 

press the SELECT ITEM soft key.

2.  Insert the USB-type flash drive into the proper connecter 

located under the protective cover on the bottom of the 

tester.

3.  Press the SELECT ITEM soft key to begin the data trans-

fer process.  When the data transfer has been successfully  

completed, the lower display will return the the Site Setup 

Menu.

Download

  The  DOWNLOAD  feature  allows  you  to  download 

data  from  a  removable  USB-type  flash  drive  to  the 

tester's internal memory.

1.  From the Main Menu use the ARROW keys to highlight 

the CQ SYNC icon and press the SELECT ITEM soft key.

2.  Highlight  the  DOWNLOAD  icon  and  press  the  SELECT 

ITEM soft key.
A FLASH UPLOAD hierarchy of the sites available for data 

upload appears on the top screen and bottom screens of 

the tester.

3.  Use the ARROW keys to highlight the Site, Plant, or String 

you  want  to  download  and  press  the  DOWNLOAD  soft 

key.

Summary of Contents for CELLTRON MAX

Page 1: ...INSTRUCTION ManuAl March 2010 167 087C CELLTRON MAX Universal Stationary Battery Analyzer For testing stationary batteries in UPS systems power utility and telecommunications industries...

Page 2: ......

Page 3: ...13 DMM 13 Utilities 13 Chapter 2 Reference Values 14 Testing Sample Jars 15 String Summary Average 15 Chapter 3 Site Setup 16 New Site 16 Create Site 16 Create Plant 16 Create String 16 Existing Site...

Page 4: ...9 Conductance Threshold 29 Date Time 29 Language 30 Mode 30 Display 30 Contrast Level 31 Backlight Time 31 Time Out 31 Straps 31 Internal Battery 31 Speaker 32 Temperature 32 Test Mode 32 Quick Test 3...

Page 5: ...y may result in a risk of electric shock or fire 1 4 Test batteries in a dry well ventilated area 1 5 Do not expose the tester to rain or snow Personal Precautions 2 1 Always have someone within range...

Page 6: ...rubber gloves Wear a protective apron or shop coat Perform service work only for which you have been trained Do not disconnect the battery cables from power systems during the test without authorizat...

Page 7: ...onnectorized Test Cable Options Dual contact clamps Dual contact probes Custom cables by quotation Power Requirements 7 2 V 2500 mAh NiMH internal swappable battery and charger Display LCD FSTN x2 66...

Page 8: ...RAQ software The CELLTRON MAX is designed for testing stationary batteries used in UPS systems power utility and telecommunications industries Also the Celltron MAX can test generator start batteries...

Page 9: ...rook IL 60527 www midtronics com CELLTRON MAX 9 CELLTRON MAX Kit CELLTRON MAX Tester IR Printer Tester cables with locking connectors for interchangeable probes and clamps Collapsable Probe Extenders...

Page 10: ...h an AC adapter 120 Vac 60 Hz Handheld printer with infrared receiver for data transmitted by the CELLTRON MAX includes battery charger output 10 2 Vdc 800 mA for charging the printer s NiMH batteries...

Page 11: ...after ap proximately 2 minutes of inactivity to conserve its battery pack 11 USB ports Thumb drive and product updates 12 AC power adapter charger port Hot Keys Eight Hot Keys are located on the botto...

Page 12: ...lection Two soft keys are located at the top of the control panel Their functions will vary depending on what mode the analyzer is in at the time Alphanumeric Entry Some selections require you to use...

Page 13: ...an serve as a digital multimeter With it you can measure DC or AC voltage and DC current Icon Function Measures voltage within a range of 0 to 18 Vdc Estimates voltage within a range of 0 to 20 V peak...

Page 14: ...ing and use the highest conductance value as a reference value Use the average from STRING SUMMARY after you test the string Refer to Using the average in STRING SUMMARY in this chapter Use REFERENCE...

Page 15: ...ar cases 3 Test the jars 4 Test one jar five times in a row on float charge Conduc tance results should be within 2 of each other NOTE If the test results do not conform to this pattern an electrical...

Page 16: ...a new Plant 1 Use the ARROW keys to highlight the character on the character map that you want to select and press the EN TER soft key to select it The character will appear on the lower screen Repeat...

Page 17: ...select and press the EN TER soft key to select it The character will appear on the lower screen Repeat this process to complete the line 2 When you ve completed the line press the NEXT soft key to sav...

Page 18: ...tep the NUM OF JAR number up or down by by one highlight the or and press ENTER The number ad vances by one each time the ENTER button is press 5 Use ARROW keys on the screen to move the cursor 6 Pres...

Page 19: ...RESH OLD and press the ENTER key The EDIT THRESHOLD CONDUCTANCE screen appears on the lower screen 2 Use the ARROW keys to select UPPER or LOWER CONDUC TANCE THRESHOLD and press the ENTER key 3 Use th...

Page 20: ...ry library or by using the unit to calculate a value based upon internal analysis of the results 1 Use the ARROW keys to highlight REFERENCE and press the ENTER key A screen appears to establish the r...

Page 21: ...r Farenheit AC Ripple This option sets the measurement for AC ripple detection DC Float V Use this option to input the float voltage of a string into the tester memory for recordkeeping DC Float A Use...

Page 22: ...hierarchy of the sites available for data upload appears on the top screen and bottom screens of the tester 2 Use the ARROW keys to highlight the Site Plant or String you want to upload and press the...

Page 23: ...DELETE soft key to complete the deletion or press the CANCEL soft key to return to the CQ SYNC menu Delete All The DELETE ALL function allows you to delete all of the site plant string and jar data st...

Page 24: ...at this process to ex pand the hierarchy to show the jar you want to retest 3 Use the ARROW keys to highlight the desired jar and press ENTER A RETEST JAR screen appears on the lower screen All Test 1...

Page 25: ...and return to the Main Menu Temperature 1 Use the ARROW keys to select TEMPERATURE and press TEST The tester will begin retesting the temperature of the selected jar using the settings saved in the T...

Page 26: ...e with an analog meter graphic 1 From the Main Menu highlight the DMM icon and press the SELECT ITEM soft key 2 Use the ARROW keys to highlight the AC VOLTS icon and press the SELECT ITEM soft key The...

Page 27: ...CHANGE TO FFT MODE to edit and press the ENTER key 2 Use the ARROW keys to increase or decrease the hori zontal scaling value Scaling options include 5ms 10ms 20ms 50ms and100ms The changes to the ho...

Page 28: ...listed manufacturer and press ENTER 3 Use ARROW keys to highlight a model name 4 Press ENTER to accept Battery detail screen appears Use ARROW keys to highlight reference and press EN TER 5 EDIT REFER...

Page 29: ...ess the ENTER key Or press the BACK soft key to return to the Main Menu without saving your changes Voltage Threshold 1 Use the ARROW keys to highlight the voltage threshold to edit and press the ENTE...

Page 30: ...t key to save your changes or the BACK soft key to return to the Main Menu without saving your changes Mode The MODE utility let s you determine if the tester au tomatically tests the next battery in...

Page 31: ...ith the ARROW keys highlight TIME OUT to edit and press the ENTER key 2 Use the ARROW keys to increase or decrease the number of minutes 3 Press ENTER to save your changes or BACK to return one screen...

Page 32: ...ar Select Celsius or Fahrenheit as the unit of measure before setting your test parameters in BATTERY SETUP The last saved TEMP selection becomes the default unit of measure 1 From the Main Menu highl...

Page 33: ...GEN BAT and press the EN TER key The CRANKING BATTERY TEST screen appears on the lower screen 2 Use the up or down ARROW keys to select between GEN ERATOR BATTERY and FLEET VEHICLE 3 Press the SAVE so...

Page 34: ...key is used to adjust the tester s in ternal speaker volume Main Menu Use the MAIN MENU hot key to jump directly to the Main Menu screen at any time Retest The RETEST hot key lets you quickly retest u...

Page 35: ...pter from the analyzer and the AC outlet NOTE The maximum charge time is 3 to 4hours Do not overcharge Replacing the analyzer battery pack If the screen does not power on after recharging replace the...

Page 36: ...ter IR transmitters and print again Make sure the printer is on The printer shuts off after two minutes of inactivity to conserve the battery To turn the printer on briefly press the MODE button The g...

Page 37: ...unit This limited warranty applies only to the CELLTRON ULTRA analyzer and does not cover any other equipment static damage water damage overvoltage damage dropping the unit or damage resulting from e...

Reviews: