Just the Facts for the Classic Lite (continued)
6 |
P a g e 1 0 - 2 0 8 - 1 R E V : A
Ground fault
There is a 2 pin header to the right of the blue terminal block for Ground Fault Protection as seen below. The
supplied jumper must be installed across both pins for the GFP to operate. The Lite is shipped with this jumper in
the open position. For GFP operation, the jumper must be placed over both pins.
Figure
3
shows the GFP jumper
pins with the shorting plug being installed.
Figure 4
shows the small black shorting jumper. This will be used to
jump the 2 pins and enable Ground Fault Protection. (Dime not included)
Non Solar inputs to the Classic Lite
The Lite will accept a wide variety of DC inputs from sources like Solar, Wind, Hydro, Fuel Cells ETC. One of the
biggest concerns when hooking the Lite to alternative sources of DC is the input Voltage.
Exceeding the Lite's Voltage window will cause damage to the Lite
.
If the source is unregulated and can exceed the Lite's maximum input voltage, a Clipper will be needed to assure the
Lite never has its voltage ratings exceeded.
Note: The Lite will need to be programed in “Custom Mode” for all applications other than Solar.
For more information on alternative inputs, please consult the Classic owner’s manual or contact technical support