Wiring Diagrams
Indoor unit wiring diagram: 16022500004023
FUNCTION OF SWITCH
SWITCH
FOR CCM UNIT ADDRESS
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0~15
S2
+
S1
ADDRESS
ON
1 2
ON
1 2
ON
1 2
ON
1 2
32~47
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
16~31
48~63
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
S2
+
S1
ADDRESS
Factory
Setting
Factory
Setting
SWITCH
FOR TEMP.COMPENSATION
SW6
ON
2
S T A T E
V A L U E
4
6
E function
F a c t o r y
S e t t i n g
ON
1 2
ON
1 2
ON
1 2
ON
1 2
SWITCH
FOR FAN MOTER
CONTROL THEN NO
POWER REQUEST.
SW2
S T A T E
M O D E
F A N O F F
F A N O N
F a c t o r y
S e t t i n g
ON
ON
ON
CN16
CN14
XS9
SWING
MOTOR
XP9
RED
Reactor
RED
CN13
DISPLAY
BOARD
TO WIRE
CONTROLLER
10
T2
T1
CN6
4
ROOM TEMP.
BLACK
WHITE
NEWFAN
CN8
M
CN10A
(CN10)
M
PUMP
2
INDOOR UNIT
MAINBOARD
CN40
TO WIRE
CONTROLLER
5
CN23
ON - OFF
Remote
Control
CN33
ALARM
Alarm
Output
Outer Driver DC Motor
Y/G
DC MOTOR
DRIVER MODLE
CN13
C
N
3
3
CN15
M
Inner Driver
DC Motor
5
M
R
ED
(B
R
O
W
N
)
CN1
B
LU
E(
B
LA
C
K
)
CN5
WATER LEVEL SWITCH
E Y X
To CCM
Comm.Bus
CN7
T2B
OUTER PIPE TEMP.
POWER
P1
CN3
JR6
JR6
FAN1
CAP1
Y/G
P3
P2
6
CN4
2
H
CH
P4
Y/G
4
BROWN
BLACK
CN110
YE
LL
O
W
Y/G
TO OUTDOOR UNIT
P5
MAGNETIC
RING
MAGNETIC RING
NOTE:
The wiring diagram
is for explanation
purpose only. The
actual shape of the
components may be
different.
16022500004023
WIRING DIAGRAM
(INDOOR UNIT)
SWITCH
FOR COOLING & HEATING
SW7
ON
S T A T E
M O D E
C O O L I N G &
H E A T I N G
C O O L I N G
O N L Y
ON
ON
F a c t o r y
S e t t i n g
OR COOLING ONLY
SETTING
8
24
15
FAN MOTOR STOP-TEM
SW1
ON
1 2
ON
1 2
ON
1 2
ON
1 2
Anti-cold air
According
to the
EEPROM
setting
Factory setting
ON
SWITCH
FOR AUTO-RESTART
SW3
ON
S T A T E
M O D E
R E M E M B E R N O _ R E M E M B E R
ON
F a c t o r y
S e t t i n g
SETTING
SWITCH
FOR MODE-PRIOR SETTING
ON
S T A T E
M O D E
H E A T
F a c t o r y
S e t t i n g
ON
1 2
ON
1 2
ON
1 2
ON
1 2
H E A T
C O O L
C O O L
SW5
106~140
161~200
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
0
8
4
1 2
3
5
6
7
C
9A
B
D
E
F
20
26
36~53
32~35
54~71
72~90
91~105
141~160
Summary of Contents for MUEU-18HRFNX-QRD0W
Page 1: ...LIGHT COMMERCIAL INVERTER SERIES SM_LC GA _R410A_R32_3D INV_EU_NA_1811 SERVICE MANUAL...
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Page 12: ...Contents 1 Model Reference 2 2 External Appearance 3 Model Reference...
Page 15: ...Model Reference 4 2 2 Outdoor Unit Outdoor Unit...
Page 19: ...IDU Compact Cassette 4 2 Dimensional Drawings...
Page 21: ...IDU Compact Cassette 6 4 Service Place...
Page 44: ...Outdoor Unit 3 Panel Plate B30...
Page 45: ...Outdoor Unit 4 Panel Plate BA30...
Page 46: ...Outdoor Unit 5 Panel Plate CA30...
Page 47: ...Outdoor Unit 6 Panel Plate D30...
Page 48: ...Outdoor Unit 7 Panel Plate E30...
Page 49: ...Outdoor Unit 8 Panel Plate 590...
Page 50: ...Outdoor Unit 9 2 Service Place...
Page 62: ...Outdoor unit printed circuit board diagram 17122000002718...