58
10.4.6 IPM malfunction or IGBT over-strong current protection diagnosis and solution(P0)
Error Code
P0
Malfunction decision
conditions
When the voltage signal that IPM send to compressor drive chip
is abnormal, the display LED will show “P0” and AC will turn off.
Supposed causes
●
Wiring mistake
●
IPM malfunction
●
Outdoor fan ass’y faulty
●
Compressor malfunction
●
Outdoor PCB faulty
Trouble shooting:
Check if the wiring between main
PCB and compressor connected by
error and if the wires and connectors
are broken?
Correct the connection or replace
the wires and connectors.
Yes
No
IPM continuity check. Check if the
IPM terminal resistance values are
uniform. Refer to page 64.
Replace the IPM board or replace the
main PCB if the IPM board and main
PCB are integrated together.
No
Check if the outdoor fan runs
properly or the outdoor unit
ventilation is good.
Yes
No
For MSV1-09HRFN1-MT0W and MSV1-12HRFN1- MT0W
models, r
efer to the solution of fan speed has been out
of control malfunction . Find out the cause and have it
solved. For other models, please refer to the below
remark, check whether the resistance of the fan motor
is normal. If not, replace the fan motor.
Yes
Check if the compressor resistance
values are uniform .Refer to page 63.
No
Replace the compressor.
Yes
Replace the outdoor main PCB if the
main PCB and IPM are separate.
Remark
:
1) MSV1-12HRDN1-MQ0W model: Measure the
black
pin and
red
pin of the motor connector, the resistance
should be around
293
Ω
at 20
℃
(68
℉
)
2) MSV1-18HRDN1-MQ0W model: Measure the
black
pin and
red
pin of the motor connector, the resistance
should be around
56
Ω
at 20
℃
(68
℉
)
3) MSV1-24HRDN1-MQ0W model: Measure the
black
pin and
red
pin of the motor connector, the resistance
should be around
56.5
Ω
at 20
℃
(68
℉
)
4)
Summary of Contents for MSV1-09HRFN1-MT0W
Page 20: ...16 6 Wiring Diagram 6 1 Indoor Unit MSV1 09HRFN1 MT0W MSV1 12HRFN1 MT0W...
Page 21: ...17 MSV1 12HRDN1 MQ0W...
Page 22: ...18 MSV1 18HRDN1 MQ0W MSV1 24HRDN1 MQ0W...
Page 23: ...19 6 2 Outdoor Unit MOC 09HFN1 MTOW MOC 12HFN1 MTOW...
Page 24: ...20 MOC 12HDN1 MQ0W...
Page 25: ...21 MOC 12HDN1 MQ0W with low ambient temp cooling function...
Page 26: ...22 MOF 18HDN1 MQ0W...
Page 27: ...23 MOF 18HDN1 MQ0W with low ambient temp cooling function...
Page 28: ...24 MOG 24HDN1 MQOW...
Page 29: ...25 MOG 24HDN1 MQOW with low ambient temp cooling function...
Page 30: ...26 MOC 09HFN1 MTOW MOC 12HFN1 MTOW...
Page 31: ...27 MOC 12HDN1 MQ0W...
Page 32: ...28 MOF 18HDN1 MQ0W MOG 24HDN1 MQOW...
Page 60: ...56...
Page 63: ...59 P U P V...
Page 64: ...60 P W P N...
Page 90: ...86 16 2 Capacitor clip 1 201200100002 35 Electric heater of chassis 1 202403100187...