70
3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
Normal resistance value
Digital tester
Normal resistance value
(+)Red
(-)Black
∞
(Several MΩ)
(+)Red
(-)Black
∞
(Several MΩ)
P
N
U
N
U
V
V
W
W
(+)Red
4: Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
RPG20B
Black - Red
381Ω±8%
(20
℃/68℉
)
(Brand: Weiling)
342
Ω±8%
(20
℃/68℉
)
(Brand: Dayang)
White - Black
267Ω±8%
(20
℃/68℉
)
(Brand: Weiling)
253
Ω±8%
(20
℃/68℉
)
(Brand: Dayang)
Summary of Contents for MSV1-09HRFN1-MT0W
Page 20: ...16 6 Wiring Diagram 6 1 Indoor Unit MSV1 09HRFN1 MT0W MSV1 12HRFN1 MT0W...
Page 21: ...17 MSV1 12HRDN1 MQ0W...
Page 22: ...18 MSV1 18HRDN1 MQ0W MSV1 24HRDN1 MQ0W...
Page 23: ...19 6 2 Outdoor Unit MOC 09HFN1 MTOW MOC 12HFN1 MTOW...
Page 24: ...20 MOC 12HDN1 MQ0W...
Page 25: ...21 MOC 12HDN1 MQ0W with low ambient temp cooling function...
Page 26: ...22 MOF 18HDN1 MQ0W...
Page 27: ...23 MOF 18HDN1 MQ0W with low ambient temp cooling function...
Page 28: ...24 MOG 24HDN1 MQOW...
Page 29: ...25 MOG 24HDN1 MQOW with low ambient temp cooling function...
Page 30: ...26 MOC 09HFN1 MTOW MOC 12HFN1 MTOW...
Page 31: ...27 MOC 12HDN1 MQ0W...
Page 32: ...28 MOF 18HDN1 MQ0W MOG 24HDN1 MQOW...
Page 60: ...56...
Page 63: ...59 P U P V...
Page 64: ...60 P W P N...
Page 90: ...86 16 2 Capacitor clip 1 201200100002 35 Electric heater of chassis 1 202403100187...