The set temperature rise 1
℃
per hour. Two hours later, the set temperature will maintain as a constant and
the fan speed is kept at low speed.
The total time is 7 hours, after 7 hours the unit stops.
11.11.3 Heating:
The set temperature decrease 1
℃
per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
The total time is 7 hours, after 7 hours the unit stops.
11.11.4 Auto:
After an hour running under economic mode, the set temp will rise 1
℃
,if it is under cooling mode; the set
temp will decrease 1
℃
,if it is under heating mode; the set temp will be changeless, if it is under fan-only
mode; the condition will be the same after the air conditioner running under economic mode after 2 hours,
and during the next time the set temp do not change. The total time is 7 hours, after 7 hours the unit stops.
11.12 Auto restart function
In case of a sudden power failure, this function automatically sets the unit to previous settings before the
power failure when power returns.
11.13 Turbo mode
In cooling mode, when pressing the turbo button on the remote controller, the unit will enter turbo mode with
ultra-high speed and reach the set temperature more quickly. After running 20 minutes in turbo mode, the
indoor fan will automatically recover the preset speed.
11.14 PLASMA ( optional)
Starts with indoor fan.
Note: Plasma and Anion can be use together.
11.15 Anion( optional)
Starts with indoor fan.
Note: Plasma and Anion can be use together.
Summary of Contents for MSE-07CR
Page 1: ...Cover MSE 07CR MSE 07HR MSE 09CR MSE 09HR MSE 12CR MSE 12HR MSE 18CR MSE 18HR...
Page 12: ...Service manual 9 5 Refrigerant cycle diagram Cooling only Heat pump mode...
Page 14: ...Service manual 11...
Page 15: ...Service manual 12 7 Schematic diagram and Wiring diagram 7 1 Schematic diagram...
Page 16: ...Service manual 13 7 2 Wiring diagram MSE 07CR MSE 09CR MSE 12CR...
Page 17: ...Service manual 14 MSE 07HR MSE 09HR MSE 12HR...
Page 25: ...Service manual 22 discharged...