9.5 Multi-function board instruction (This multi-function board is optional)
9.5.1. Function
The multi-function board receives the signal of 4-cored wired controller(central controller),Non-polar
wired controller and CP remote on-off signal( ON-OFF command signal) . Then converting it to the
communication signal to the main control board.
The multi-function board can output Alarm signal.
The multi-function board has two versions, one for Non-polar wired controller, the other one for 4-cored
wired controller or central controller.
9.5.2. CP remote on-off
9.5.2.1 This is the same as the LCAC, that is to say for the first time, when you active this function, you
need firstly use remote controller to turn on the unit .After setting, when the unit are running, you can
use the on-off function to turn off the units and display will show CP, when you use this function again,
the display will cancel CP and the unit will run as the last situation.
9.5.2.2 If need this function, the switches F2 should be settled as below:
Dip-switch 2
Dip-switch 1
Remote on-off control status
OFF
OFF
Disconnected send CP, closed cancel CP
ON
OFF
Closed send CP, disconnected cancel CP
9.5.3. ON-OFF control
9.5.3.1 With on-off command, you can directly use this function regardless remote controller.The
indoor will be turned on and off by this port. But indoor will still get order from remote controller when it
is turned off by this port. when the indoor is turned on by this port, the unit will run in Auto mode ,Auto
fan speed, 24
℃
setting temperature
9.5.3.2 If need this function, the switches F2 should be settled as below:
Dip-switch 2
Dip-switch 1
Remote on-off control status
OFF
ON
Disconnected send ON, closed send OFF
ON
ON
Closed send OFF
,
disconnected send ON
9.5.4. 4-cored wired controller
,
Central controller and Non-polar wired controller
Note: 4-cored wired controller
,
Central controller and Non-polar wired controller
are mutually exclusive. They can only be chosen one of three at the same time.
9.5.4.1 For network address, Dip-switch F1 and Rotary switch ENC3 are set as below:
Dip-switch 2
Dip-switch 1
Based address
OFF
OFF
0
OFF
ON
16
ON
OFF
32
ON
ON
48
Summary of Contents for MOB31-12HFN1-QRD0GW
Page 1: ...All Easy 3D Inverter Series Service Manual 2017 ...
Page 8: ...8 For MSAEAU 09HRFN1 QRD0GW MSAEAU 09HRFNX QRD0GW ...
Page 10: ...10 For MSAEDU 24HRFN1 QRD0GW MSAEDU 24HRFN1 QRD0GW B MSAEDU 24HRFNX QRD0GW ...
Page 11: ...11 3 2 Outdoor Unit ...
Page 14: ...14 For MOCA30 24HFN1 QRD0GW MOCA30 24HFN1 QRC8GW ...
Page 31: ...31 MOB31 18HFN1 QRD0GW MOCA30 24HFN1 QRD0GW MOCA30 24HFN1 QRC8GW ...