and prevents household things freezing
when the house is unoccupied for a long time in
severe cold weather.
9.4.11 Self clean(optional)
For heat pump models which are provided with
this function, after running in cooling or drying
mode, if the user press “Self Clean” button on
remote controller, firstly, indoor unit runs in fan
only mode for a while, then low heat operation
and finally runs in fan only again. This function
can keep the inside of indoor unit dry and
prevent breeding of mold.
9.4.12 Follow me(optional)
1) If the indoor PCB receives the signal which
results from pressing the FOLLOW ME button
on remote controller, the buzzer will emit a
sound and this indicates the follow me function
is initiated. But when the indoor PCB receives
signal which sent from remote controller every
3 minutes, the buzzer will not respond. When
the unit is running with follow me function, the
PCB will control the unit according to the
temperature from follow me signal, and the
temperature collection function of room
temperature sensor will be shielded, but the
error detective function of room temperature
sensor will be still valid.
2) When the follow me function is available,
the PCB will control the unit according to the
room temperature from the remote controller
and the setting temperature.
3) The PCB will take action to the mode
change information from remote controller
signal, but it will not affected by the setting
temperature.
4) When the unit is running with follow me
function, if the PCB doesn’t receive any signal
from remote controller for 7 minutes or pressing
FOLLOW ME button again, the follow me
function will be turned off automatically, and the
temperature will control the unit according to
the room temperature detected from its own
room
temperature
sensor
and
setting
temperature.
9.4.13 Silence operation(optional)
Press the “silence” button on remote controller
to initiate SILENCE function. When the Silence
function is activated, the compressor running
frequency will keep lower than F2 and the
indoor unit will bring faint breeze, which will
reduce the noise to the lowest level and create
a quiet and comfortable room for you.
9.4.14 Easy control(optional)
For AE series
,
On-off port, XYE port, WIFI
,
wired controller(5-cored) can be chosen at the
same time. Non-polar wired controller,4-cored
wired controller, and central controller are
mutually exclusive.
Summary of Contents for MOB31-12HFN1-QRD0GW
Page 1: ...All Easy 3D Inverter Series Service Manual 2017 ...
Page 8: ...8 For MSAEAU 09HRFN1 QRD0GW MSAEAU 09HRFNX QRD0GW ...
Page 10: ...10 For MSAEDU 24HRFN1 QRD0GW MSAEDU 24HRFN1 QRD0GW B MSAEDU 24HRFNX QRD0GW ...
Page 11: ...11 3 2 Outdoor Unit ...
Page 14: ...14 For MOCA30 24HFN1 QRD0GW MOCA30 24HFN1 QRC8GW ...
Page 31: ...31 MOB31 18HFN1 QRD0GW MOCA30 24HFN1 QRD0GW MOCA30 24HFN1 QRC8GW ...