8. Operation Characteristics
Mode
Temperature
Cooling operation
Heating operation
Drying operation
Room
temperature
17
℃
~32
℃
(62
℉
~90
℉
)
0
℃
~30
℃
(32
℉
~86
℉
)
10
℃
~32
℃
(50
℉
~90
℉
)
Outdoor
temperature
0
℃
~50
℃
(32
℉
~122
℉
)
-15
℃
~30
℃
(5
℉
~86
℉
)
0
℃
~50
℃
(32
℉
~122
℉
)
-15
℃
~50
℃
(5
℉
~122
℉
)
(For the models with
low temperature
cooling system)
-25
℃
~50
℃
(-13
℉
~122
℉
)
(For
MSAECU-18HRFN1-QRD0
GW(S1))
CAUTION:
1. If the air conditioner is used beyond the above conditions, certain safety protection features
may come into operation and cause the unit to operate abnormally.
2. The room relative humidity should be less than 80%. If the air conditioner operates beyond this
figure, the surface of the air conditioner may attract condensation. Please set the vertical air flow
louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
3. For units with auxiliary electric heater .When outside temperature is below 0°C(32°F ),we
strongly recommend keeping the unit plugged in at all times to ensure smooth ongoing performance.
4. The optimum performance will be achieved during this operating temperature zone.