8.3.5 Open or short circuit of temperature sensor diagnosis and solution.
8.3.6 Compressor voltage protection
Yes
Replace outdoor PCB
Yes
Check the connections between
the sensors and the PCB. Are the
connections good?
Replace the sensor and check if
the errors happen again?
Check the voltage of power supply, if the voltage is about 220V, turn off the power
supply to indoor unit and turn it on again after 1 minute
Does the trouble occur again?
Check the voltage of P,N port in IPM board.
If it is not higher than 310V, follow the below step.
Replace the IPM board
Yes
No