ODMI-1103-A
8.3.8 Temperature protection of compressor discharge or compressor top.
Yes
Does
compressor
operate?
Is
the
connection
good?
Is refrigerant
circulation
volume
normal?
No
No
Charge
refrigerant
Is abnormality
the same after
gas charging?
No
Check refrigerant system
(such
as
clogging
of
capillary, etc)
Reconnect and retest.
No
Yes
Is
protector
normal?
Replace the protector.
No
Yes
Check
the
outdoor
main
PCB.
Is
there
some problem?
Replace the outdoor
PCB.
Yes